Technical data

15

15.1General technical data

General technical data

AC device: Supply voltage

100 to 240 V AC (85 to 265 V AC)

DC device: Supply voltage

24 V DC (20.4 to 28.8 V DC) SELV

AC device: Frequency

50 - 60 Hz (47 to 63 Hz)

Transient voltage interruption

AC device: At least 20 ms for 93 to 264 V

according to Namur

at most 10 events per hour; recovery time of at least 1 s

 

DC device: no buffering

AC device: Max. power consumption of complete unit

360 W primary with approx. 65% efficiency

at 240 W secondary

 

DC device: Max. power consumption of complete unit

265 W primary with approx. 70% efficiency

at 180 W secondary

 

AC device: max. current output

+5 V/25 A *)

 

+3.3 V/10 A *)

 

*) 155 W total allowed

 

+12 V/12.2 A peak 14.0A

 

–12 V/0.8 A

 

–5 V/0.5 A limited to >0.8 A

 

+5 Vaux/2 A peak 2.5 A

 

The total voltage amounts to max. 230 W.

DC device: max. current output

+5 V/22 A *)

 

+3.3 V/16 A *)

 

*) 140 W total allowed

 

+12 V/4.4 A peak 8.0 A

 

–12 V/0.5 A

 

–5 V/0.5 A

 

+5 Vaux/1 A

 

The total voltage amounts to 180 W.

Noise emission

< 55 dB(A) according to DIN 45635-1

Degree of protection for complete unit on rear

IP 20

Degree of protection on front with tension jack

IP 65

mouniting

 

Degree of protection on front with screw mouniting

IP 54

SIMATIC Panel PC 877

15-1

Operating instructions, Release 07/2006, A5E00877780-01

Page 171
Image 171
Siemens PANEL PC 877 operating instructions Technical data, General technical data