Technical data 15.1 General technical data
Permissible temperature ranges depending on the installation method
Panel PC 877
Complete unit | Internal cabinet | Ambient | Comment |
| temperature | temperature |
|
|
| cabinet |
|
Installed in cabinet | 50 °C | 40 °C | 1)4) |
different temperatures |
|
|
|
Installed in cabinet | 45 °C | 45 °C | 2)4) |
Same temperature inside and outside |
|
|
|
Computer unit and control unit separated, |
|
|
|
using Remote Kit |
|
|
|
12" control unit | 50 °C | 45 °C |
|
15" control unit | 50 °C | 45 °C |
|
19" v | 50 °C | 45 °C | 5) |
Computer unit, Intel ® Pentium 4 Mobile | 55 °C | - | 3)4) |
2.2 GHz, 400 MHz |
|
|
|
These values are applicable for vertical installation and when air is flowing through the cabinet.
1)Max. PCI load 50 W
2)Full expansion, max. PCI load 75 W (5 slots)
3)PCI modules are not permitted
4)Above 40 °C, optical drives must not be operated
5)When the 19" front is operated at ambient temperatures between 45 °C and 50 °C, the USB interface of the Remote Kit (rear USB interface) must not be used.
SIMATIC Panel PC 877 | |
Operating instructions, Release 07/2006, |