Technical data

15.1 General technical data

General technical data

Safety

Protection class

Protection class I to IEC 60536, i.e.: Device with PE ground terminal

 

Standards

IEC 60950-1, EN 60950-1, DIN EN 60950-1, EN 61131-2

 

Approvals

AC device: cULus in accordance with UL 60950-1

 

 

DC device: cULus in accordance with UL 508

 

Conformity

CE

 

Degree of protection

With clamp attachment, encircling seal and pressed-on plastic cap for

IP 65, NEMA 4

 

USB interface 5)

 

 

With screw attachment

IP 54

Liability of product

24 months

 

nonconformance

 

 

Quality assurance

to ISO 9001

 

1) Limitations for optical drives:

Burner operation is only allowed without external disruptions and at an ambient temperature between +5° C and +40° C.

2) Limitation for optical drives:

10 to 58 Hz: 0.019 mm / 58 to 500 Hz: 2.5 m/s2 approx. 1/4 g. Burner operation is only allowed without external disruptions.

3)Electrically isolated within the safety extra-low voltage circuit, SELV.

4)A small number of faults in the display is unavoidable. However, the displays do comply with the described quality standards of the ISO stanard 13406-2, class 2.

Bad pixels

Permissible number

Permanently bright and permanently dark pixels

≤ 12

Permanently bright, green pixels

≤ 5

5)The front USB interface cannot be used in some device variants.

6)USB 2.0 standard.