11.2 Safecard on Motherboard (SOM)

 

 

 

 

 

 

(1)

Temperature range

Here the current temperature and limit values are shown. You can

 

 

 

toggle the temperature display mode to indicate either the current

 

 

 

temperature, or the min./max. values measured since the start of the

 

 

 

application.

 

 

 

(1a)

Internal processor temperature

 

 

 

(1b)

Device temperature beneath the power supply:

 

 

 

 

upper threshold can be set from 30°C to 80°C

 

 

 

(1c)

Cooling air temperature surrounding the DVI connector:

 

 

 

 

- depending on device 3°C to 5°C higher than the ambient

 

 

 

 

temperature

 

 

 

 

- upper threshold can be set from 25°C to 55°C

 

(2)

Watchdog range

Here, you can configure the watchdog function in your monitoring

 

 

 

application. You can specify the watchdog time, activate a PC reset

 

 

 

and activate / deactivate the watchdog.

 

(3)

Fan area

You can read the current fan speed in this area.

 

 

 

(3a)

Fan speed in the area close to the processor

 

 

 

(3b)

Fan speed on the power supply

The description of the drivers and SOM software for Windows is available on the "Documentation and Drivers" CD under Drivers/Tools >Tools>PPC877.