Detailed descriptions 17.1 Motherboard

PROFIBUS/MPI interface, X400

The PROFIBUS/MPI socket has the following pinout:

PROFIBUS/MPI interface 1)

PinNo.

Abbreviation

Meaning

Input/Output

1

Not assigned

2

Not assigned

3

LTG_B

Signal line B of MPI module

Input/output

4

RTS_AS

RTSAS, control signal for received data

Input

 

 

stream. The signal is "1" active when the

 

 

 

directly connected PLC is sending.

 

5

M5EXT

M5EXT return line (GND) of the 5 V power

Output

 

 

supply. The current load caused by an external

 

 

 

consumer connected between P5EXT and

 

 

 

M5EXT must not exceed the maximum of 90

 

 

 

mA.

 

6

P5 EXT

P5EXT power supply (+5 V) of the 5 V power

Output

 

 

supply. The current load caused by an external

 

 

 

consumer connected between P5EXT and

 

 

 

M5EXT must not exceed the maximum of 90

 

 

 

mA.

 

7

Not assigned

8

LTG_A

Signal line A of MPI module

Input/output

9

RTS_PG

RTS output signal of the MPI module. The

Output

 

 

control signal is "1" when the PG is sending.

 

Shieldin

 

on connector casing

 

g

 

 

 

1)Optional product feature