Troubleshooting/FAQs

14

14.1General problems

This chapter provides you with tips on how to localize and troubleshoot frequently occurring problems.

Problem

Possible causes

To correct or avoid error

The device is not

There is no power supply

Check the power supply, the network cable and the power plug.

operational

to the device.

Check whether the On/Off switch is in the correct position.

 

Device is being operated

Check the ambient conditions.

 

outside the specified

After transport in cold weather, wait approximately 12 hours

 

ambient. conditions

 

before switching on the device.

The mouse pointer

The mouse driver is not

1.

Check whether the mouse driver is properly installed and present

does not appear on

loaded.

 

when you start the application program.

the screen.

 

 

 

The mouse is not

1.

Check whether the mouse lead is connected to the system unit. If

 

 

connected.

 

you are using an adapter or an extension for the mouse lead,

 

 

 

check this plug-in connection too.

 

 

 

After these checks and measures, if the mouse pointer still does

 

 

 

not appear on the screen, please contact Technical Customer

 

 

 

Support.

Wrong time and/or

 

1.

Press <F2> within the boot sequence to open the BIOS Setup.

date on the PC.

 

2.

Set the time and date in the setup menu.

 

 

Although the BIOS

The backup battery is

In this case, please contact your technical support team.

setting is OK, the time

dead.

 

 

and data are still

 

 

 

wrong.

 

 

 

USB device not

The USB ports are

Use a different USB port or switch the port on.

responding.

disabled in your BIOS.

 

 

 

USB 2.0 device

Enable USB 2.0.

 

connected but USB 2.0 is

 

 

 

disabled.

 

 

 

Operating system does

Enable USB Legacy Support for the mouse and keyboard.

 

not support the USB port.

For all other devices you need USB drivers for the specific operating

 

 

system.

DVD: The front loader

The device is switched off

Emergency removal of the data medium:

does not open.

or the open/close button

1.

Switching off the device

 

is disabled by a software

 

2.

Insert a pointed object, a pin for example, or an opened paper clip

 

application.

 

 

 

into the emergency extraction opening of the drive. Apply slight

 

 

 

pressure to the contact until the front loader opens.

 

 

3.

Pull the loader further out.

SIMATIC Panel PC 877

 

 