Application planning 4.5 Mounting cut-out

Table 4-1

Dimensions for the mounting cut-out in mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control unit

 

L1

L2

L3 1)

L4 1)

L5

L6 2)

L7 2)

L8 2)

L9 2)

A1

A2

S1

S2

S53)

S63)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S3

 

S73)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S4

 

 

Tolerance

 

+1

+1

±0.2

±0.5

±0.5

±0.5

±0.5

+1

±1

±1

±1

±1

±1

±1

 

Key panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12" TFT

 

450

290

465

235

112

16

10

78

78

56

15" TFT

 

450

321

465

279

112

186

135

25

165

16

17

51

51

56

Touch panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15" TFT

 

450

290

465

235

112

16

10

81

81

56

19" TFT

 

450

380

465

235

112

16

10

46

46

33

1)M6 thread or drilled holes of 7 mm diameter

2)Cut-outs for the slots or inserted labels are required for 15'' key panels only

3)Two clamps are required vertically for clamp mounting for the 19' touch panels only

Preparing the mounting cut-out

Steps for preparing the mounting cut-out

1Select a location suitable for mounting, taking into account the mounting position.

2On the basis of the dimension diagrams, check whether the required screw and pressure points on the rear and the seal area are easily accessible after the completion of the mounting cut-out. Otherwise the mounting cut-out is useless.

3Complete the mounting cut-out in accordance with the dimensions.

4-10

SIMATIC Panel PC 877

Operating instructions, Release 07/2006, A5E00877780-01

Page 34
Image 34
Siemens PANEL PC 877 Preparing the mounting cut-out, S53, Tolerance, Steps for preparing the mounting cut-out