Technical data
15.1 General technical data
General technical data
Electromagnetic compatibility (EMC)
AC device: Emitted interference | EN 55011 Class A, EN | |
|
| EN |
DC device: Emitted interference | EN 55022 Class A | |
Noise immunity: | ± 2 kV; according to IEC | |
Mains borne disturbance variables on supply lines | ± 1 kV; according to IEC | |
|
| ± 2 kV; according to IEC |
Noise immunity on signal lines | ± 1 kV;according to IEC | |
|
| ± 2 kV; according to IEC |
|
| ± 2 kV; according to IEC |
Immunity to discharges of static electricity | ± 6 kV contact discharge according to IEC | |
|
| ± 8 kV air discharge according to IEC |
Immunity to RF interference | 10 V/m | |
|
| 10 V/m 900 MHz and 1.89 GHz, 50% ED according to IEC 61000– |
|
| |
|
| 10 V/m 9 |
Magnetic field | 30 A/m, 50 Hz according to IEC | |
Climatic conditions |
| |
Temperature | Tested to IEC | |
• | Operation | • + 5 °C up to + 45 °C |
• | Installed in cabinet: | • Internal temperature max. 50 °C |
| – For external temperature of 40 °C | |
| – For external temperature of 45 °C | • Internal temperature max. 45 °C |
• | Storage, transportation | • |
• | Gradient | • max. 10° C/h in operation, 20° C/h storage, no condensation |
Relative humidity | Tested to IEC | |
• | Operation | • 5% to 80 % at 25° C, no condensation |
• | Storage/transport | • 5% to 95% at 25° C, no condensation |
• | Gradient | • Maximum 10° C/h, no condensation |
|
| |
Mechanical environmental conditions |
| |
Vibration | tested to DIN IEC | |
• | Operation2) | • 10 to 58 Hz: 0.075 mm, 58 to 500 Hz: 9.8 m/s2 = 1g |
• | Storage/transport | • 5 to 9 Hz: 3.5 mm, 9 to 500 Hz: 9.8 m/s2 = 1g |
Resistance to shock | Tested according to IEC | |
• | Operation2) | • 50 m/s2 approx. 5 g, 30 ms |
• | Storage/transport | • 250 m/s2 approx. 25 g, 6 ms |
SIMATIC Panel PC 877 | |