Detailed descriptions 17.1 Motherboard

I/O front interface for operator panels, X44

This interface carries all signals required for the connection of operator panels in addition to the display and USB interface. The maximum cable length is 50 cm at a USB data rate of 12 Mbps.

Pin No.

Abbreviation

Meaning

Input/Output

1

GND

Ground

-

2

P12V

Inverter voltage supply

Output

3

BL_ON

Backlight ON (5 V = ON)

Output

4

P5V_fused

+5 V (fused)

Output

5

GND

Ground

-

6

P3V3_fused

+3.3 V VCC (fused)

Output

7

K_CLK

Keyboard clock channel

Output

8

K_DATA

Keyboard data channel

Input/Output

9

M_CLK

Mouse clock channel

Output

10

K_DATA

Mouse data channel

Input/Output

11

P5V_fused

+5 V (fused)

Output

12

USB_D1M

USB data channel 1

Input/Output

13

USB_D1P

USB data+, channel 1

Input/Output

14

GND

Ground

-

15

LCD_SEL0

Display type - Select signal 0

Input

16

LCD_SEL1

Display type - Select signal 1

Input

17

LCD_SEL2

Display type - Select signal 2

Input

18

LCD_SEL3

Display type - Select signal 3

Input

19

RESET_N

Reset signal (active low)

Input

20

Power button

Power button function front

Input

21

HD_LED

HD LED, anode with 1 kW in series on the

Output

 

 

motherboard

 

22

DP_LED

MPI/DP LED, anode via 1 kohm in series on the

Output

 

 

motherboard

 

23

Ethernet_LED

Ethernet LED, anode with 1 kW in series on the

Output

 

 

motherboard

 

24

TEMP_ERR

Temperature error LED, anode with 1 kW in series

Output

 

 

on the motherboard

 

25

RUN_R

Watchdog error LED, anode with 1 kW in series on

Output

 

 

the motherboard

 

26

RUN_G

Watchdog OK LED, anode with 1 kW in series on

Output

 

 

the motherboard

 

17-16

SIMATIC Panel PC 877

Operating instructions, Release 07/2006, A5E00877780-01

Page 208
Image 208
Siemens PANEL PC 877 operating instructions Front interface for operator panels