Detailed descriptions 17.1 Motherboard
17.1.5Front interfaces
Overview
Interface | Position | Connector | Description |
Display (LVDS) | Internal | X300 | Connection of LCD displays with |
|
|
| LVDS interface (channel 1) |
Display (LVDS) | Internal | X310 | Connection of LCD displays with |
|
|
| LVDS interface (channel 2) |
I/O front | Internal | X44 | Interface for I/O front |
COM2 | Internal | X33 | Internal COM2 interface |
USB | Internal | X2033 | Internal USB 2.0 interface (USB |
|
|
| channel 5) |
Display interfaces
TFT displays with an LVDS interface can be connected to this interface. You may connect
The display power supply voltages (3.3V and 5V) are switched via the graphic controller, independent of the requirements of the connected display units. The maximum cable length is 50 cm at a transmission rate of 455 MHz. Make allowances for the special channel features of differential line pairs with LVDS specifications.
SIMATIC Panel PC 877 | |
Operating instructions, Release 07/2006, |