Super Systems Inc. Page 17 SDS Data Logger Manual #4565 Rev D
1. Overview Display
The Overview Display shows the current readings of the five thermocouples on all four or eight boards,
depending on the number of channels. Pressing the circular arrow key will display the

Quick Chart screen

(menu option 16). Pressing the up or down arrow keys will display the

Modify Input Offsets

screen
(menu option 9). Pressing any of the number keys (1-9) will display the corresponding menu option.
2. Display Survey Information
The Display Survey Information shows the survey information on the top half of the screen. Included is
the Template name, Company name, Furnace ID, Action (start or stop the survey), Survey Temperature
Setpoint, A field to edit the survey values, The Date/Time the survey was started and the Date/Time the
survey was stopped. Pressing the up or down arrow keys will scroll through the Action, Setpoint and Edit
survey fields. Pressing Enter on the line “To edit survey values Press ’Enter’” will display the

Modify

Survey Information

screen (menu option 19), which allows the user to modify some of the information
used in the survey. Currently, the only information that can be modified are the Setpoint, TC units, and
TC spool correction.
To start the survey, highlight the Action field, enter a 1 and then press Enter. Once a survey has been
started, “Testing” will appear in the highlighted area and the start Date/Time will be filled in the “Started
at” field.