Action-Qualifier Submodule Registers

Figure 4-10. Action-Qualifier Output B Control Register (AQCTLB)

15

 

 

12

11

10

9

8

 

Reserved

 

 

 

CBD

 

CBU

 

R-0

 

 

 

R/W-0

 

R/W-0

7

6

5

4

3

2

1

0

 

CAD

 

CAU

 

PRD

 

ZRO

 

R/W-0

 

R/W-0

 

R/W-0

 

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

Table 4-10. Action-Qualifier Output B Control Register (AQCTLB) Field Descriptions

Bits

Name

Value

Description

15-12

Reserved

 

 

11-10

CBD

 

Action when the counter equals the active CMPB register and the counter is decrementing.

 

 

00

Do nothing (action disabled)

 

 

01

Clear: force EPWMxB output low.

 

 

10

Set: force EPWMxB output high.

 

 

11

Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.

9-8

CBU

 

Action when the counter equals the active CMPB register and the counter is incrementing.

 

 

00

Do nothing (action disabled)

 

 

01

Clear: force EPWMxB output low.

 

 

10

Set: force EPWMxB output high.

 

 

11

Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.

7-6

CAD

 

Action when the counter equals the active CMPA register and the counter is decrementing.

 

 

00

Do nothing (action disabled)

 

 

01

Clear: force EPWMxB output low.

 

 

10

Set: force EPWMxB output high.

 

 

11

Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.

5-4

CAU

 

Action when the counter equals the active CMPA register and the counter is incrementing.

 

 

00

Do nothing (action disabled)

 

 

01

Clear: force EPWMxB output low.

 

 

10

Set: force EPWMxB output high.

 

 

11

Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.

3-2

PRD

 

Action when the counter equals the period.

 

 

 

Note: By definition, in count up-down mode when the counter equals period the direction is defined

 

 

 

as 0 or counting down.

 

 

00

Do nothing (action disabled)

 

 

01

Clear: force EPWMxB output low.

 

 

10

Set: force EPWMxB output high.

 

 

11

Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.

1-0

ZRO

 

Action when counter equals zero.

 

 

 

Note: By definition, in count up-down mode when the counter equals 0 the direction is defined as 1

 

 

 

or counting up.

 

 

00

Do nothing (action disabled)

 

 

01

Clear: force EPWMxB output low.

 

 

10

Set: force EPWMxB output high.

 

 

11

Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.