www.ti.com

Trip-Zone Submodule Control and Status Registers

 

Table 4-16.

PWM-Chopper Control Register (PCCTL) Bit Descriptions (continued)

Bits

Name

Value

Description

10-8

CHPDUTY

 

Chopping Clock Duty Cycle

 

 

000

Duty = 1/8 (12.5%)

 

 

001

Duty = 2/8 (25.0%)

 

 

010

Duty = 3/8 (37.5%)

 

 

011

Duty = 4/8 (50.0%)

 

 

100

Duty = 5/8 (62.5%)

 

 

101

Duty = 6/8 (75.0%)

 

 

110

Duty = 7/8 (87.5%)

 

 

111

Reserved

7:5

CHPFREQ

 

Chopping Clock Frequency

 

 

000

Divide by 1 (no prescale, = 12.5 MHz at 100 MHz SYSCLKOUT)

 

 

001

Divide by 2 (6.25 MHz at 100 MHz SYSCLKOUT)

 

 

010

Divide by 3 (4.16 MHz at 100 MHz SYSCLKOUT)

 

 

011

Divide by 4 (3.12 MHz at 100 MHz SYSCLKOUT)

 

 

100

Divide by 5 (2.50 MHz at 100 MHz SYSCLKOUT)

 

 

101

Divide by 6 (2.08 MHz at 100 MHz SYSCLKOUT)

 

 

110

Divide by 7 (1.78 MHz at 100 MHz SYSCLKOUT)

 

 

111

Divide by 8 (1.56 MHz at 100 MHz SYSCLKOUT)

4:1

OSHTWTH

 

One-Shot Pulse Width

 

 

0000

1 x SYSCLKOUT / 8 wide ( = 80 nS at 100 MHz SYSCLKOUT)

 

 

0001

2 x SYSCLKOUT / 8 wide ( = 160 nS at 100 MHz SYSCLKOUT)

 

 

0010

3 x SYSCLKOUT / 8 wide ( = 240 nS at 100 MHz SYSCLKOUT)

 

 

0011

4 x SYSCLKOUT / 8 wide ( = 320 nS at 100 MHz SYSCLKOUT)

 

 

0100

5 x SYSCLKOUT / 8 wide ( = 400 nS at 100 MHz SYSCLKOUT)

 

 

0101

6 x SYSCLKOUT / 8 wide ( = 480 nS at 100 MHz SYSCLKOUT)

 

 

0110

7 x SYSCLKOUT / 8 wide ( = 560 nS at 100 MHz SYSCLKOUT)

 

 

0111

8 x SYSCLKOUT / 8 wide ( = 640 nS at 100 MHz SYSCLKOUT)

 

 

1000

9 x SYSCLKOUT / 8 wide ( = 720 nS at 100 MHz SYSCLKOUT)

 

 

1001

10 x SYSCLKOUT / 8 wide ( = 800 nS at 100 MHz SYSCLKOUT)

 

 

1010

11 x SYSCLKOUT / 8 wide ( = 880 nS at 100 MHz SYSCLKOUT)

 

 

1011

12 x SYSCLKOUT / 8 wide ( = 960 nS at 100 MHz SYSCLKOUT)

 

 

1100

13 x SYSCLKOUT / 8 wide ( = 1040 nS at 100 MHz SYSCLKOUT)

 

 

1101

14 x SYSCLKOUT / 8 wide ( = 1120 nS at 100 MHz SYSCLKOUT)

 

 

1110

15 x SYSCLKOUT / 8 wide ( = 1200 nS at 100 MHz SYSCLKOUT)

 

 

1111

16 x SYSCLKOUT / 8 wide ( = 1280 nS at 100 MHz SYSCLKOUT)

0

CHPEN

 

PWM-chopping Enable

 

 

0

Disable (bypass) PWM chopping function

 

 

1

Enable chopping function

4.6Trip-Zone Submodule Control and Status Registers

Figure 4-17and Table 4-17provide the trip-zone control and status register definitions.

106

Registers

SPRU791D–November 2004–Revised October 2007

Submit Documentation Feedback

Page 106
Image 106
Texas Instruments TMS320x28xx, 28xxx manual Trip-Zone Submodule Control and Status Registers, Chpduty