See page 142 for the operation of the advanced setup.

Wake on RS-232C access RS-232C STANDBY

Use this feature to set this unit to transmit data via the RS-232C interface when this unit is in the standby mode.

Choice

Functions

 

 

YES

Select this setting to set this unit to transmit data via the

 

RS-232C interface.

 

 

NO

Select this setting to set this unit not to transmit data via

 

the RS-232C interface.

 

 

Initial setting:

[U.S.A. Canada models]: YES

[Other models]: NO

Network standby NET STANDBY

Use this feature to select whether this unit accepts the commands via LAN network when this unit is in the standby mode (see page 120).

Choice

Functions

 

 

YES

Accepts the operations via LAN network when this unit

 

is in the standby mode.

 

 

NO

Does not accept the operations via LAN network when

 

this unit is in the standby mode.

 

 

Note

If you set “NET STANDBY” to “YES”, the amount of power consumption in the standby mode is increased.

Remote control ID setting REMOTE CON AMP

Use this feature to set the remote control ID of this unit for remote control recognition.

Choice

Descriptions

 

 

ID1

Select this setting when the ID of the remote control is

 

set to “ID1”

 

 

ID2

Select this setting when the ID of the remote control is

 

set to “ID2”

 

 

Setting remote control ID

Use this feature to set the remote control ID. This feature is useful when you control multiple Yamaha AV receiver or amplifier with using the remote control.

Press GID repeatedly using a ballpoint pen or similar object on the remote control to select the desired remote control ID.

Each time you press GID, the remote control ID indicator changes as shown below.

ID1

ID

ID2

y

To set the remote control ID of the simplified remote control, see page 132 for details.

Advanced setup

Cooling fan operation mode FAN MODE

Use this feature to set the operation of the cooling fan of this unit.

Choice

Descriptions

 

 

AUTO

Select this setting to set the fan to operate automatically

 

according to the temperature of this unit.

 

 

CONT.

Select this setting to set the fan to activate continuously

 

regardless of the temperature of this unit.

 

 

Bi-amplifier mode BI-AMP

Use this feature to activate or deactivate the bi-amplifier function.

Choice

Descriptions

 

 

ON

Select this setting if you want to activate the bi-amplifier

 

function.

 

 

OFF

Select this setting if you want to deactivate the bi-

 

amplifier function.

 

 

Note

When “BI-AMP”is set to “ON”, the SUR.BACK/BI-AMP terminals cannot be used to connect surround back speakers in that the SUR.BACK/BI-AMP terminals are already used for the bi-amplifier connection (see page 28).

Pre-amplifier mode PREAMP MODE

Use this feature to select whether you use this unit as the pre- amplifier in the main zone and use all the internal amplifiers for the other zones.

Choice

Descriptions

 

 

ON

Select this setting when you use this unit as the pre-

 

amplifier in the main zone. The audio signals for the

 

main zone are only output at the PRE OUT jacks of this

 

unit. You can assign all speaker terminals for the other

 

zones.

 

 

OFF

Select this setting to use the internal amplifiers of this

 

unit for the main zone, Zone 2, Zone 3, or Zone 4.

 

 

Recovery and backup of the system settings

RECOV./BACKUP

Use this feature to save and restore the settings of this unit.

Choice

Select

 

 

RECOVERY

Restoring the saved setting of this unit.

 

 

BACKUP

Saves the current settings of this unit.

 

 

CANCEL

Cancels the recovery or backup of the settings of this

 

unit.

 

 

Notes

This unit does not save the FM/AM preset stations, preset network/USB items, and system memory settings.

If no settings are saved, you cannot select “RECOVERY”.

Operation

Advanced

 

 

143 En