ZyXEL Communications Prestige 153/153X WAN Bridge/Routers, Field, Description, Options

Models: 153X 153

1 177
Download 177 pages 43.26 Kb
Page 79
Image 79
Manual background

 

 

Prestige 153/153X WAN Bridge/Routers

Table 4-1.

Remote Node Profile Menu Fields for Dial-up Lines (continued)

 

 

 

 

Field

 

Description

Options

 

 

 

 

Edit PPP Options

To edit the PPP options for this remote node, move the

Press space bar

to select [Yes]

 

 

cursor to this field, use the space bar to select [Yes] and

 

 

then press [Enter]

 

 

press [Enter]. This will bring you to Menu 11.2 - Remote

 

 

 

 

 

Node PPP Options. For more information on configuring

 

 

 

PPP options, see the section Editing PPP Options.

 

 

 

 

 

Rem IP Addr

 

This is a required field [?] if IP routing is enabled. Enter

 

 

 

the IP address of the remote gateway.

 

 

 

 

 

Edit IP/IPX/Bridge Options

To edit the parameters, select [Yes] and press [Enter].

Press space bar

to select [Yes]

 

 

This will bring you to Menu 11.3 – Remote Node

 

 

then press [Enter]

 

 

Network Layer Options. For more information on this

 

 

 

 

 

screen, refer to the chapter pertaining to your specific

 

 

 

protocol.

 

 

 

 

 

Edit Script Options

To edit the parameters, select [Yes] and press [Enter].

Select [Yes] then

press [Enter]

 

 

This will bring you to Menu 11.4 – Remote Node Script.

 

 

 

 

 

 

 

Telco Option:

 

 

 

Allocated Budget

This field sets a ceiling for outgoing call time to this

Default = 0

(min)

 

remote node. The default for this field is [0] for no

 

 

 

budget control.

 

Period (hr)

 

This field will set the time interval to reset the above

 

 

 

outgoing call budget control.

 

 

 

 

Session Options:

In these fields, enter the filter set(s) you wish to apply to

Default=Blank

 

 

the incoming and outgoing traffic between this remote

 

Input Filter Sets,

node and your Prestige. You can choose from 12

 

Output Filter Sets and

different filter sets. In addition, you can link up to 4 filter

 

Call Filter Sets

sets together for further customization, e.g., 1, 5, 9, 12.

 

 

 

Note that spaces are accepted in this field.

 

 

 

For more information on customizing your filter sets, see

 

 

 

Chapter 9. The default is blank, i.e., no filters defined.

 

 

 

 

 

Remote Node Configuration

4-7

Page 79
Image 79
ZyXEL Communications Prestige 153/153X WAN Bridge/Routers, Remote Node Profile Menu Fields for Dial-up Lines continued