Image 74
•[Switch] for dial-up lines.

Prestige 153/153X WAN Bridge/Routers

Menu 11. - Remote Node Setup

1.________

2.________

3.________

4.________

Enter Node # to Edit:

Figure 4-1. Menu 11 - Remote Node Setup

Step 3. When Submenu 11.1. - Remote Node Profile appears, select the type of line that will be used (dial-up line or leased line). Set the Connection Type to one of the following values:

[Switch] for dial-up lines.

[Leased] for leased lines. Selecting [Leased] will bring you to Submenu 11.1.2 - Remote Node Profile for leased line.

 

Menu 11.1 - Remote Node Profile

 

Rem Node Name=

?

Device Type= 56K Modem

Active= Yes

 

Route= IP

 

Connection Type= Switch

Bridge= No

 

Call Direction= Both

Edit PPP Options= No

Incoming:

 

Rem IP

Addr= ?

 

Rem Login= ?

 

Edit IP/IPX/Bridge=

No

Rem Password=

?

Edit Script Options= No

Rem CLID=

 

Telco Option:

 

Call Back= No

 

Allocated Budget(min)= 0

Outgoing:

 

Period(hr)= 0

 

My Login= ?

 

Session Options:

 

My Password= ?

Input Filter Sets=

 

Authen= CHAP/PAP

Output Filter Sets=

Pri Phone #= ?

Call

Filter Sets=

 

Sec Phone #=

 

Idle

Timeout(sec)=

300

Press ENTER to CONFIRM or ESC to CANCEL:

Press Space Bar to Toggle.

Figure 4-2. Menu 11.1 - Remote Node Profile for Dial-up Lines