Hardware Design
2.If a
To maintain signal integrity and minimize
Refer to following termination guidelines for
1.
Recommend less than 200 mils if possible. Follow the manufacturer’s recommendation for the termination value needed to obtain the required 45 ohm to ground parallel HS termination.
2.For downstream ports, a 15 kΩ pull down resistor on the connector side of the termination is required for device connection detection purposes. Note that this pull down might be integrated into the host controller silicon. Follow the manufacturer’s recommendation for the specific part used.
3.A common mode (CM) choke should be used to terminate the high speed USB bus if they should pass EMI testing. Place the CM choke as close as possible to the connector as shown in Figure 8 on page 36. Common mode chokes can provide required noise attenuation. Design can include a common mode choke footprint to provide a stuffing option in the event the choke is needed to pass EMI testing.
Note: Common mode chokes degrade signal quality, thus they should only be used if EMI is a known problem.
Figure 7. Common Mode Choke