Intel IXP43X manual EMI Design Considerations, Trace Impedance, Power and Ground Plane

Page 65

Hardware Design Guidelines—Intel®IXP43X Product Line of Network Processors

Space within a group can be just 1 w.

Space between clock signals or clock to any other signal should be 3 w. The coupled noise between adjacent traces decreases by the square of the distance between the adjacent traces.

5.2.6EMI Design Considerations

It is strongly recommended that good electromagnetic interference (EMI) design practices must be followed while designing with the IXP43X network processors.

Information on spread-spectrum clocking is available in the Intel® IXP4XX Product Line of Network Processors and IXC1100 Control Plane Processor: Spread- Spectrum Clocking to Reduce EMI Application Note.

Place high-current devices as closely as possible to the power sources.

Proper termination of signals can reduce reflections, which can emit a high- frequency component that contribute to more EMI than the original signal itself.

Ferrite beads can be used to add high frequency loss to a circuit without introducing power loss at DC and low frequencies. They are effective when used to absorb high-frequency oscillations from switching transients or parasitic resonances within a circuit.

Keep rise and fall times as slow as possible. Signals with fast rise and fall times contain many high-frequency harmonics which can radiate significantly.

A solid ground is essential at the I/O connector to chassis and ground plane.

Keep the power plane shorter than the ground plane by at least 5x the spacing between the power and ground planes.

Stitch together all ground planes around the edge to the board every 100 to 200 mil. This helps reduce EMI radiating out of the board from inner layers.

5.2.7Trace Impedance

All signal layers require controlled impedance of 50 Ω ±10 % microstrip or stripline (unless otherwise specified) where appropriate. Selecting the appropriate board stack- up to minimize impedance variations is very important.

When calculating flight times, it is important to consider the minimum and maximum trace impedance based on the switching neighboring traces.

5.2.8Power and Ground Plane

Power and ground planes should have sufficient decoupling capacitors to ensure sustainable current needed for high-speed switching devices. See Section 3.14.1, “Decoupling Capacitance Recommendations” on page 54.

It is highly recommended to use sufficient internal power and ground planes.

The Intel® IXP43X Product Line requires a number of power supplies. It is appropriate to use power islands in the power plane under the processor, as it will be too expensive to have a power plane for each power source.

Power islands must be large enough to include the required power supply decoupling capacitance, and the necessary connection to the voltage source and destination.

Islands can be separated by a minimum of 20-mil air gap.

Use at least one via per power or ground pin, wherever possible use more vias, depending on current drawn.

 

Intel® IXP43X Product Line of Network Processors

April 2007

HDG

Document Number: 316844; Revision: 001US

65

Image 65
Contents Hardware Design Guidelines Intel IXP43X Product Line of Network ProcessorsApril Intel IXP43X Product Line of Network ProcessorsHDG Contents Figures Tables Document Number 316844 Revision 001US 001 Initial release § §Date Revision Description HDG Chapter Name Description Content OverviewAcronyms Related DocumentationList of Acronyms and Abbreviations Sheet 1 Term ExplanationList of Acronyms and Abbreviations Sheet 2 OverviewHDG Intel IXP435 Network Processor Block Diagram Typical Applications System Memory Map System Architecture DescriptionIntel IXP43X Product Signal Type Definitions Soft Fusible FeaturesSoft Fusible Features Sheet 1 Symbol DescriptionUSB Host Each USB can be Enable separately Soft Fusible Features Sheet 2DDRII/I Sdram Interface EthernetDDRII/I Sdram Interface Pin Description Sheet 1 Signal InterfaceType Name Device-Pin Connection Terminatio Description FieldDDRII/I Sdram Interface Pin Description Sheet 2 DDRII/I Sdram InitializationType Pull Name Recommendations Field Down Expansion Bus Signal Recommendations Sheet 1Expansion Bus Expansion Bus Signal Recommendations Sheet 2 Reset Configuration StrapsBoot/Reset Strapping Configuration Sheet 1 Name Type Pull Recommendations Field DownBoot/Reset Strapping Configuration Sheet 2 3 8-Bit Device Interface Setting Intel XScale Processor Operation SpeedIntel XScale Processor Cfg0 Cfg1 Cfgenn Actual Core Speed MHz4 16-Bit Device Interface 16-Bit Device Interface Flash InterfaceFlash Interface Example Uart InterfaceUart Signal Recommendations Uart Interface Example MII InterfaceMII NPE C Signal Recommendations Sheet 1 Signal Interface MIIMII NPE a Signal Recommendations Device Connection, MII MII NPE C Signal Recommendations Sheet 2MAC Management Signal Recommendations NPE a and NPE C MII Interface Example Gpio InterfaceDesign Notes Gpio Signal RecommendationsUSB Interface Name Type Pull Description Field Down USB Host Signal RecommendationsCommon Mode Choke Host Device Type Pull Name Description Field Down Utopia Level 2 InterfaceUtopia Level 2/MIIA UTPOPDATA75 UTPOPDATA4UTPOPADDR40 UtpopfciUtpipfci ClavUtpipsoc ETHARXDATA30 EtharxclkUTPIPDATA6 UTPIPDATA5UTPIPDATA7 UTPIPADDR40Device Connection HSS InterfaceHSSTXDATA0 High-Speed, Serial InterfaceHSSTXCLK0 HSSRXDATA0HSS Interface Example SSP InterfaceSynchronous Serial Peripheral Port Interface Serial Flash and SSP Port SPI Interface Example PCI InterfacePCI Controller Sheet 1 PCI Controller Sheet 2 PCI Interface Block DiagramPciintan PciclkinPCI Option Interface Connect signal to same pin between PCI Parity Two devicesPCI Host/Option Interface Pin Description Sheet 1 Type Option Description Name Device-Pin Connection FieldSignal PCIREQN0 to one PCIREQN30 inputs to the Host On the Option device, these signals are notPCI Host/Option Interface Pin Description Sheet 2 Type Option Name Device-Pin Connection Description FieldPCI Host/Option Interface Pin Description Sheet 3 Jtag InterfaceClock Signals Clock SignalsInput System Clock Clock OscillatorRecommendations for Crystal Selection Nominal Name Voltage Description PowerPower Supply Reset Timing Power SequenceDecoupling Capacitance Recommendations VCC Decoupling§ § PCB Overview Component PlacementGeneral Recommendations Component SelectionStack-Up Selection Component Placement on a PCBControlled-impedance traces Low-impedance power distribution Layer Stackup General Layout Guidelines General Layout and Routing GuideGeneral Component Spacing Signal Changing Reference PlanesGood Design Practice for VIA Hole Placement Pad-to-Pad Clearance of Passive Components to a PGA or BGA Clock Signal ConsiderationsCrosstalk MII Signal ConsiderationsUSB V2.0 Considerations Trace Impedance Power and Ground PlaneEMI Design Considerations § § Topology Electrical Interface@33 MHz Tcyc = 30 nSec Tval = 11 nSec Tprop = 10 nSecParameter Routing Guidelines Clock DistributionPCI Address/Data Routing Guidelines PCI Clock Routing Guidelines Trace Length LimitsRouting Guidelines Signal LoadingIntroduction Ddrii / Ddri SdramGroup Signal Name Description DDRII/I Signal GroupsDrasn / Ddrrasn Dcasn / DdrcasnDDR Sdram Supported Ddrii 32-bit Sdram Configurations Supported Ddri 32-bit Sdram ConfigurationsSupported Ddri 16-bit Sdram Configurations SizeaDDRII/DDRI Rcomp and Slew Resistances Pin Requirements Supported Ddrii 16-bit Sdram ConfigurationsAddress Size Leaf Select Total Technology Arrangement BanksDDR Clock Timings DDR-II Symbol Parameter Units Min MaxDdrii OCD Pin Requirements DDR Sdram Write Timings Symbol Parameter Minimum Nominal Maximum Units DDRII-400 MHz Interface -- Signal TimingsSymbol Parameter Minimum Nom Maximum Units DDR II/I Sdram Interface -- Signal TimingsTiming Relationships Printed Circuit Board Layer StackupTiming Relationships Signal Package Lengths Sheet 1Group Signal Name Length mil Signal Package Lengths Sheet 2 Clock Group Signal Package Lengths Sheet 3Parameter Definition Data and Control GroupsDCB70/DDRCB70, DDQ310 / DDRDQ310 Ddrii Data and Control Signal Group Routing GuidelinesSignal Group Members Ddrii Command Signal Group Routing Guidelines§ §