Fuji Labs ZSP instruction manual Standard Accessories and Spares, Standard accessories

Page 44

11. STANDARD ACCESSORIES AND SPARES

Caution

Do not use replacement parts which are not specified by makers. Use of these parts will not only provide the required performance but also result in damage or other trouble.

Replacement parts used for maintenance must be handled as incombustible objects.

11.1Standard accessories

No.

Part name

Type of part No.

Quantity (analyzer)

 

Remarks

 

 

 

 

NOX/SO2

NOX

SO2

Other

 

 

 

 

1

Membrane filter paper

TK701837C6

1 pack

1 pack

25 sheets per pack

 

 

 

 

 

 

 

 

2

Flouro pour filter for

TK741833P3

2

2

 

 

membrane filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Fuse (for instrument switch)

Various types

2 each

2 each

2 each

2 each

For 2A, 3.2A

 

 

 

 

 

 

 

 

4

Cooler puller

1

1

1

1

 

 

 

 

 

 

 

 

 

5

Joint

TK7F7627P1

1 set

1 set

1 set

1 set

Measuring number of gases + 1

 

 

 

 

 

 

 

For pressure regulator

 

 

 

 

 

 

 

 

6

Hose band

TK539474C410

100%

100%

100%

100%

For ø6 tube

 

 

 

 

 

 

 

For pressure regulator

 

 

 

 

 

 

 

 

7

Toalon tube 0.3m

TK727528P1

1

1

1

1

For ø6 tube

 

 

 

 

 

 

 

 

8

Polyethylene tube 1m

415966P4

1 set

1 set

1 set

1 set

ø6/ø4 For standard gas

 

 

 

 

 

 

 

 

9

Anchor bolt

M12 x 160 x 50

4

4

4

4

Option

 

 

 

 

 

 

 

 

10

Instruction manual

INZ-TN2ZSP

1

1

1

1

 

 

 

INZ-TN2ZRG

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Analyzer accessories

 

1 set

1 set

1 set

1 set

Infrared analyzer fuse 2A x 2pcs.

 

 

 

 

 

 

 

Cell cleaning cloth x 1pc.

 

 

 

 

 

 

 

O2 analyzer fuse x 1pc.

12

Wash bottle

TK7H3493P1

1

1

1

1

For conditioner

 

 

 

 

 

 

 

 

Note) Part No. 8 will be shipped in connection with the solenoid valve in the locker.

– 36 –

Image 44
Contents Infrared GAS Analyzer Introduction RequestProhibition Iii Prohibition Others Contents Vii Specifications OutlineComposition PreparedSelection of gas sampling location InstallationSelection of installation site Installation work Connection of cablesPiping procedure Injection of clean water Supply of external powerDescription of Each Part Preparation for OperationWarm-up time Setting of temperature inside lockerAirtightness test INDICATION/OPERATION Panel SO2Function and indication of indication/operation panel This panel consists of the following functionsAdvice on Operation General operation of indication/operation panelPreparation of standard gas CalibrationKinds of standard gas Pressure regulation for standard gas cylinder Calibration concentration setting except zirconia O2 sensor Func CAL SET ENTCAL Calibration concentration setting zirconia O2 sensor CAL Comp ENT Zero Single-component analyzer Auto calibration Auto CAL Func Auto CAL Func Auto CAL ENT Auto calibration ON/OFF setting Func Hold ENT Operating procedure OperationMaintenance Routine maintenance and inspectionConditioner Periodic maintenance and inspection Other maintenance and inspectionCentration is measured in the setting range of 0 to 200ppm or more at 0.5L/minMaintenance of sampling device Gas extractor type ZBAK1Membrane filter Exploded view of diaphragm type aspirator Structure of electronic dehumidifier Structure of NO2 /NO converter Structure of Permapure dryer Maintenance of zirconia O2 sensor Others, major component figuresStandard Accessories and Spares Standard accessoriesSpares for 1 year optional Code for preparation of 1-year spares and suppliesProcessing of Heating Pipe Ends OutlineEnd processing method Grid 300mm 40mm Grid area 150 mm Check after piping Clamp supportSpecifications of tube trace Specifications of heating pipeTroubleshooting Troubleshooting of instrumentError codes and remedies Ambient temperature Power supplyPower consumption Mass weightNumber of output points and kinds of outputs Standard requirements For sample gasMonth/NO2, 100ppm Block diagram Moving average outputAutomatic calibration Ordering informationCalibration tolerance Automatic calibration output hold Calibration cycle Once/day variable, up to 7 daysCode Symbols Diaglam Functions of individual components For outdoor installation type For indoor installation typeConnection Diagram Only specified outputs are wiredHead Office Instrumentation Div International Sales Dept