7.INDICATION/OPERATION PANEL
7.1Name and description of each component of indication/operation panel
2 Main indication
1 Component indication
|
|
|
|
|
| Vol% | SU TU TH SA |
| |
|
|
| NOX |
|
|
|
| RANCE | |
|
|
|
|
|
|
|
| ||
|
|
|
|
| ppm |
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| MO WE FR |
| |
|
|
| SO2 |
|
| Vol% |
|
| RANCE |
|
|
|
|
|
|
|
| ||
|
|
|
|
| ppm |
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
| O2 |
|
| Vol% |
|
| RANCE |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
7 | Function indicator lamp | HEAS | CAL SET | SET | HOLD |
| RANCE | AUTO SAL | |
|
|
| FUNC | COMP |
| ENT | ZERO | SPAN | CAL |
| 8 | Function key |
|
|
|
|
|
|
|
| 9 | Component selector key |
|
|
|
|
|
|
|
| 10 | Digit shift key |
|
|
|
|
|
|
|
| 11 | Numeric input key |
|
|
|
|
|
|
|
3Unit indication lamp
4Day indication
5Sub indication
6Range changeover switch
15Calibration start key
14Span calibration key
13Zero calibration key
12ENT key
|
| (Three component of NOx, SO2 and O2 are indication in this figure.) | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Part Name |
|
|
|
| Description |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
q Component indication | Indicates kind of gas measured. |
|
|
|
|
|
|
|
|
|
|
| |||
w Main indication | Indicates measured concentration. Also indicates various | ||||||||||||||
| calibration function (option), etc. |
|
|
|
|
|
|
|
|
|
|
| |||
e Unit indication lamp | Indicates units of measured gas concentration. |
|
|
|
|
|
|
|
|
| |||||
r Day indication | Indicates current day or day of starting by means of bar in auto calibration (option) setting mode. | ||||||||||||||
| Indication | SU | MO | TU | WE | TH | FR | SA | |||||||
| Day Sun. | Mon. | Tue. | Wed. | Thu. | Fri. | Sat. |
|
|
|
|
|
| ||
t Sub indication | Indicates measuring range, error code, various set points, etc. |
|
|
|
|
|
| ||||||||
y Range changeover key | Used when changing the range. High range is set when pressing | and low range is set when | |||||||||||||
| pressing . |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
u Function indicator lamp | Relevant lamp lights up when following functions are set. |
|
|
|
|
|
| ||||||||
MEAS: | Lights up in measuring status. |
|
|
|
|
|
|
|
|
|
|
| |||
CAL SET: | Flashes in calibration concentration setting mode. |
|
|
|
|
|
|
| |||||||
ALM SET: | Flashes in alarm setting mode. |
|
|
|
|
|
|
|
|
|
|
| |||
HOLD: | Flashes in hold setting mode or lights steadily while hold function is activated. | ||||||||||||||
RMT RANGE: | Flashes in remote range setting mode or light steadily while remote range function is activated. | ||||||||||||||
AUTO CAL: | Flashes in auto calibration setting mode or lights steadily while auto calibration function is | ||||||||||||||
| activated. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
i Function key | Setting mode is changed at each press of this key (Refer to Section 5). | ||||||||||||||
o Component selector key | Set component is changed for each setting mode. |
|
|
|
|
|
|
| |||||||
!0Digit shift key | Shift is made from highest toward lowest digit at each press of this key. | ||||||||||||||
!1Numeric input key | Selected digit is incremented at each press of this key. |
|
|
|
|
|
|
| |||||||
!2ENT key | By pressing this key after setting, the set contents are memorized and becomes valid. | ||||||||||||||
!3Zero calibration key | Used for zero point calibration. (Lamp flashes in zero calibration mode.) | ||||||||||||||
!4Span calibration key | Used for span calibration (Lamp flashes in span calibration mode.) | ||||||||||||||
!5Calibration start key |
|
|
|
|
|
|
|
|
|
|
| ||||
Start key for manual calibration. Zero is calibrated by pressing |
|
| ZERO | and | CAL | keys. | |||||||||
| Span is calibrated by pressing | SPAN | and | CAL | keys. (CAL lamp lights steadily during calibra- | ||||||||||
| tion). |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|