Fuji Labs ZSP instruction manual Connection Diagram, Only specified outputs are wired

Page 61

CONNECTION DIAGRAM

1

L1

 

 

 

 

 

 

 

 

2

L2

 

 

 

 

 

 

 

 

 

 

 

3

G

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

5

J1

 

 

 

 

 

 

 

 

 

 

 

6

J2

 

 

 

 

 

 

 

 

 

 

 

7

H1

 

 

 

 

 

 

 

 

 

 

 

8

H2

 

 

 

 

 

 

 

 

 

 

 

9

A1

 

 

 

 

 

 

 

 

10

A2

 

 

 

 

 

 

 

 

 

 

 

11

A3

 

 

 

 

 

 

 

 

12

A4

 

 

 

 

 

 

 

 

 

 

 

13

B1

 

 

 

 

 

 

 

 

14

B2

 

 

 

 

 

 

 

 

 

 

 

15

B3

 

 

 

 

 

 

 

 

16

B4

 

 

 

 

 

 

 

 

 

 

 

17

C1

 

 

 

 

 

 

 

 

18

C2

 

 

 

 

 

 

 

 

 

 

 

19

C3

 

 

 

 

 

 

 

 

20

C4

 

 

 

 

 

 

 

 

 

 

 

21

C5

 

 

 

 

 

 

 

 

22

C6

 

 

 

 

 

 

 

 

 

 

 

23

C1A

 

 

 

 

 

 

 

 

24

C2A

 

 

 

 

 

 

 

 

 

 

 

25

E1

 

 

 

 

 

 

 

 

26

E2

 

 

 

 

 

 

 

 

 

 

 

27

E3

 

 

 

 

 

 

 

 

28

E4

 

 

 

 

 

 

 

 

 

 

 

29

C7

 

 

 

 

 

 

 

 

30

C8

 

 

 

 

 

 

 

 

 

 

 

31

D11

 

 

 

 

 

 

 

 

32

D12

 

 

 

 

 

 

 

 

 

 

 

33

D21

 

 

 

 

 

 

 

 

 

 

 

34

D22

 

 

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

36

 

 

 

 

 

 

 

 

 

Note: Terminal numbers are fixed.

(only specified outputs are wired).

Power supply 100V AC

Extractor

Heating tube

NOx instantaneous value

NOx average value

SO2 instantaneous value

SO2 average value

O2 instantateous value

NOX instantateous value

SO2 corrected value

O2 instantateous value

CO instantaneous value

CO average value

CO corrected value

Failure contact output

On maintenance and auto calibration contact output

– 53 –

Image 61
Contents Infrared GAS Analyzer Request IntroductionProhibition Iii Prohibition Others Contents Vii Outline SpecificationsComposition PreparedSelection of installation site InstallationSelection of gas sampling location Connection of cables Installation workPiping procedure Supply of external power Injection of clean waterDescription of Each Part Preparation for OperationAirtightness test Setting of temperature inside lockerWarm-up time SO2 INDICATION/OPERATION PanelThis panel consists of the following functions Function and indication of indication/operation panelGeneral operation of indication/operation panel Advice on OperationKinds of standard gas CalibrationPreparation of standard gas Pressure regulation for standard gas cylinder Func CAL SET ENT Calibration concentration setting except zirconia O2 sensorCAL Calibration concentration setting zirconia O2 sensor CAL Comp ENT Zero Single-component analyzer Auto calibration Auto CAL Func Auto CAL Func Auto CAL ENT Auto calibration ON/OFF setting Func Hold ENT Operation Operating procedureRoutine maintenance and inspection MaintenanceConditioner Other maintenance and inspection Periodic maintenance and inspectionCentration is measured in the setting range of 0 to 200ppm or more at 0.5L/minGas extractor type ZBAK1 Maintenance of sampling deviceMembrane filter Exploded view of diaphragm type aspirator Structure of electronic dehumidifier Structure of NO2 /NO converter Structure of Permapure dryer Others, major component figures Maintenance of zirconia O2 sensorStandard accessories Standard Accessories and SparesCode for preparation of 1-year spares and supplies Spares for 1 year optionalOutline Processing of Heating Pipe EndsEnd processing method Grid 300mm 40mm Grid area 150 mm Clamp support Check after pipingSpecifications of heating pipe Specifications of tube traceTroubleshooting of instrument TroubleshootingError codes and remedies Power supply Ambient temperaturePower consumption Mass weightMonth/NO2, 100ppm Standard requirements For sample gasNumber of output points and kinds of outputs Moving average output Block diagramOrdering information Automatic calibrationCalibration tolerance Automatic calibration output hold Calibration cycle Once/day variable, up to 7 daysCode Symbols Diaglam Functions of individual components For indoor installation type For outdoor installation typeOnly specified outputs are wired Connection DiagramHead Office Instrumentation Div International Sales Dept