Fuji Labs ZSP Spares for 1 year optional, Code for preparation of 1-year spares and supplies

Page 45

11.2 Spares for 1 year (optional)

No.

Part name

 

 

Quantity (analyzer)

 

 

Remarks

 

 

 

 

 

 

 

 

 

NOX/SO2

 

NOX

SO2

 

Other

 

 

 

 

 

 

 

 

 

1

Spare for converter

 

Note 2)1

 

1

 

Catalyst and filter

TK726889C3

2

Conditioner filter

 

2

 

2

2

 

2

TK7H8043P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Conditioner O-ring

 

2

 

2

2

 

2

G65 chloproprene

8553765

 

 

 

 

 

 

 

 

 

 

 

4

Membrane filter paper

 

 

1 pack

 

1 pack

25 sheets of TK701837C6 per pack

 

 

 

 

 

 

 

 

 

 

 

5

Fluro pour filter for membrane filter

6

 

6

 

TK741833P3

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Membrane filter rubber ring

1

 

1

1

 

1

Chloroprene

 

TK733572P1

 

 

 

 

 

 

 

 

 

 

 

 

7

Membrane filter O-ring

 

1

 

1

1

 

1

G65 chloroprene

 

8553765

 

 

 

 

 

 

 

 

 

 

 

 

8

Capillary

 

1

 

1

 

For 0.5 K

 

 

 

 

 

 

 

 

 

 

 

(only when with pressure control valve)

 

 

 

 

 

 

 

 

 

 

 

9

Capillary (for bypass)

 

1

 

1

1

 

1

TK729264C6 (ø1mm)

 

 

 

 

 

 

 

 

 

(only when without pressure control valve)

 

 

 

 

 

 

 

 

 

 

10

Capillary (for cooler out)

1

 

1

1

 

1

TK729264C7 (ø1.4mm)

 

 

 

 

 

 

 

 

 

(only when without pressure control valve)

 

 

 

 

 

 

 

 

 

 

 

 

11

Aspirator diaphragm

 

1

 

1

1

 

1

TK725417P5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Aspirator valve

 

1

 

1

1

 

1

TK725417P6

 

 

 

 

 

 

 

 

 

 

 

 

13

Gas extractor filter element

1

 

1

1

 

1

TK7H8439P1

When gas extractor is

 

 

 

 

 

 

 

 

 

 

simultaneously supplied.

14

Gas extractor O-ring

P48A

2

 

2

2

 

2

85504N3

 

 

(ZBAK1)

Note 1) The contents of standard accessories, and spares and supplies for 1 year may vary somewhat according to the specifications.

Note 2) Two parts are required when flow rate is 0.5N and NO range is beyond 200 ppm.

Code for preparation of 1-year spares and supplies

Analysis gas

Extractor

Code

Remarks

 

 

 

 

NOx, SO2, (CO), (O2)

With

ZBN4SP12

SO2 meter range 200 to 1000ppm

Same as above

Without

ZBN4SP22

SO2 meter range 200 to 1000ppm

NOx, (CO), (O2)

With

ZBN4SP32

 

Same as above

Without

ZBN4SP42

 

 

 

 

 

SO2, (O2)

With

ZBN4SP52

SO2 meter range 200 to 1000ppm

Same as above

Without

ZBN4SP62

SO2 meter range 200 to 1000ppm

CO, (O2)

With

ZBN4SP72

 

Same as above

Without

ZBN4SP82

 

 

 

 

 

– 37 –

Image 45
Contents Infrared GAS Analyzer Request IntroductionProhibition Iii Prohibition Others Contents Vii Outline SpecificationsComposition PreparedInstallation Selection of installation siteSelection of gas sampling location Connection of cables Installation workPiping procedure Supply of external power Injection of clean waterDescription of Each Part Preparation for OperationSetting of temperature inside locker Airtightness testWarm-up time SO2 INDICATION/OPERATION PanelThis panel consists of the following functions Function and indication of indication/operation panelGeneral operation of indication/operation panel Advice on OperationCalibration Kinds of standard gasPreparation of standard gas Pressure regulation for standard gas cylinder Func CAL SET ENT Calibration concentration setting except zirconia O2 sensorCAL Calibration concentration setting zirconia O2 sensor CAL Comp ENT Zero Single-component analyzer Auto calibration Auto CAL Func Auto CAL Func Auto CAL ENT Auto calibration ON/OFF setting Func Hold ENT Operation Operating procedureRoutine maintenance and inspection MaintenanceConditioner Other maintenance and inspection Periodic maintenance and inspectionCentration is measured in the setting range of 0 to 200ppm or more at 0.5L/minGas extractor type ZBAK1 Maintenance of sampling deviceMembrane filter Exploded view of diaphragm type aspirator Structure of electronic dehumidifier Structure of NO2 /NO converter Structure of Permapure dryer Others, major component figures Maintenance of zirconia O2 sensorStandard accessories Standard Accessories and SparesCode for preparation of 1-year spares and supplies Spares for 1 year optionalOutline Processing of Heating Pipe EndsEnd processing method Grid 300mm 40mm Grid area 150 mm Clamp support Check after pipingSpecifications of heating pipe Specifications of tube traceTroubleshooting of instrument TroubleshootingError codes and remedies Power supply Ambient temperaturePower consumption Mass weightStandard requirements For sample gas Month/NO2, 100ppmNumber of output points and kinds of outputs Moving average output Block diagramOrdering information Automatic calibrationCalibration tolerance Automatic calibration output hold Calibration cycle Once/day variable, up to 7 daysCode Symbols Diaglam Functions of individual components For indoor installation type For outdoor installation typeOnly specified outputs are wired Connection DiagramHead Office Instrumentation Div International Sales Dept