Fuji Labs ZSP instruction manual Standard requirements For sample gas, Month/NO2, 100ppm

Page 54

Standard requirements

 

 

 

 

for sample gas:

Temperature

60 to 800° C

 

Dust

— 100 mg/Nm3 or less

 

Pressure

-2.94 to +2.94kPa

 

Components

SO2

0 to 1000ppm

 

 

 

NOx

0 to 2000ppm (NO2 100ppm or less)

 

 

 

CO2

several % to over 10%

 

 

 

CO

0 to 2000ppm

 

 

 

O2

0.5 to 21%

 

 

 

H2O

0 to 40%

 

 

 

HCN

0 to 100ppm

 

 

 

N2

remaining percent

When other components are contained in the sample gas, consult with Fuji.

Note) NO2/NO converter catalyst life: 1 year/NO2, 10ppm

1month/NO2, 100ppm

Installation requirements: Select a location free from direct sunlight and severe vibration.

Table 1 Number of output points and kinds of outputs

Type

ZSP1L

ZSP1F

ZSP1P

ZSP1B

ZSP1A

ZSP1H

ZSP1M

 

 

 

 

 

 

 

 

Measuring

NOx, SO2,

NOx, SO2,

NOx, O2

CO, O2

SO2, (O2)

NOx, CO2, O2

NOx, SO2,

component

CO, O2

O2

 

 

 

 

CO, CO2, O2

No. of

11

7

3

3

3

5

12

output points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Kind of output

A, B, C,

A, B, D, E,

A, D, E

C, D, K

B, (D)

A, B, D, E, K

A, B, C,

 

D (2 points), E,

F, H, J

 

 

 

 

D (2 points),

 

F, G, H, J, K

 

 

 

 

 

E, F, G, H, J,

 

 

 

 

 

 

 

K, L

 

 

 

 

 

 

 

 

A: NOx instantaneous value

 

B: SO2 instantaneous value

 

C: CO instantaneous value

 

D: O2 instantaneous value

 

E: NOx instantaneous value after O2 correction

F: SO2 instantaneous value after O2 correction

G: CO instantaneous value after O2 correction

H: 1hr. moving average NOx value after O2 correction

J: 1hr. moving average SO2 value after O2 correction

K: 4hr. moving average CO value after O2 correction

L: O2 instanteneous value

 

 

 

 

 

– 46 –

Image 54
Contents Infrared GAS Analyzer Introduction RequestProhibition Iii Prohibition Others Contents Vii Composition SpecificationsOutline PreparedInstallation Selection of installation siteSelection of gas sampling location Installation work Connection of cablesPiping procedure Description of Each Part Injection of clean waterSupply of external power Preparation for OperationSetting of temperature inside locker Airtightness testWarm-up time INDICATION/OPERATION Panel SO2Function and indication of indication/operation panel This panel consists of the following functionsAdvice on Operation General operation of indication/operation panelCalibration Kinds of standard gasPreparation of standard gas Pressure regulation for standard gas cylinder Calibration concentration setting except zirconia O2 sensor Func CAL SET ENTCAL Calibration concentration setting zirconia O2 sensor CAL Comp ENT Zero Single-component analyzer Auto calibration Auto CAL Func Auto CAL Func Auto CAL ENT Auto calibration ON/OFF setting Func Hold ENT Operating procedure OperationMaintenance Routine maintenance and inspectionConditioner Centration is measured in the setting range of 0 to Periodic maintenance and inspectionOther maintenance and inspection 200ppm or more at 0.5L/minMaintenance of sampling device Gas extractor type ZBAK1Membrane filter Exploded view of diaphragm type aspirator Structure of electronic dehumidifier Structure of NO2 /NO converter Structure of Permapure dryer Maintenance of zirconia O2 sensor Others, major component figuresStandard Accessories and Spares Standard accessoriesSpares for 1 year optional Code for preparation of 1-year spares and suppliesProcessing of Heating Pipe Ends OutlineEnd processing method Grid 300mm 40mm Grid area 150 mm Check after piping Clamp supportSpecifications of tube trace Specifications of heating pipeTroubleshooting Troubleshooting of instrumentError codes and remedies Power consumption Ambient temperaturePower supply Mass weightStandard requirements For sample gas Month/NO2, 100ppmNumber of output points and kinds of outputs Block diagram Moving average outputCalibration tolerance Automatic calibration output hold Automatic calibrationOrdering information Calibration cycle Once/day variable, up to 7 daysCode Symbols Diaglam Functions of individual components For outdoor installation type For indoor installation typeConnection Diagram Only specified outputs are wiredHead Office Instrumentation Div International Sales Dept