Fuji Labs ZSP instruction manual Code Symbols

Page 57

CODE SYMBOLS

1

2

3

4

5

6

7

8

 

9

10 11

12

 

 

 

Z

S

P

 

 

 

 

4

 

 

 

 

 

 

Descrption

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustion exhaust gas (standard condition)

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

Other exhaust gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Component

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

NOX + (O2)

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

CO + (O2)

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

SO2 + (O2)

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

NOX + SO2 + (O2)

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

NOX + SO2 + CO + (O2)

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

NOX + SO2 + CO + (O2)

 

 

 

 

 

Z

 

 

 

 

 

 

 

 

 

Others

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oxygen analyzer

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

Without

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

With ZFK

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

With ZKG (Non-standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto calibration

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

With

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of cubicle

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

Indoor installation type

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

Outdoor installation type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External piping

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

Heating pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ø10 Teflon tube

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

Standard gas

13.4r

210r

33.4r + instrument air

410r+ instrument air

53.4r + atmopheric air

610r+ atmopheric air

Power supply

5100V AC/50Hz

6100V AC/60Hz

9

Others 50Hz

0

Others 60Hz

– 49 –

Image 57
Contents Infrared GAS Analyzer Request IntroductionProhibition Iii Prohibition Others Contents Vii Outline SpecificationsComposition PreparedInstallation Selection of installation siteSelection of gas sampling location Connection of cables Installation workPiping procedure Supply of external power Injection of clean waterDescription of Each Part Preparation for OperationSetting of temperature inside locker Airtightness testWarm-up time SO2 INDICATION/OPERATION PanelThis panel consists of the following functions Function and indication of indication/operation panelGeneral operation of indication/operation panel Advice on OperationCalibration Kinds of standard gasPreparation of standard gas Pressure regulation for standard gas cylinder Func CAL SET ENT Calibration concentration setting except zirconia O2 sensorCAL Calibration concentration setting zirconia O2 sensor CAL Comp ENT Zero Single-component analyzer Auto calibration Auto CAL Func Auto CAL Func Auto CAL ENT Auto calibration ON/OFF setting Func Hold ENT Operation Operating procedureRoutine maintenance and inspection MaintenanceConditioner Other maintenance and inspection Periodic maintenance and inspectionCentration is measured in the setting range of 0 to 200ppm or more at 0.5L/minGas extractor type ZBAK1 Maintenance of sampling deviceMembrane filter Exploded view of diaphragm type aspirator Structure of electronic dehumidifier Structure of NO2 /NO converter Structure of Permapure dryer Others, major component figures Maintenance of zirconia O2 sensorStandard accessories Standard Accessories and SparesCode for preparation of 1-year spares and supplies Spares for 1 year optionalOutline Processing of Heating Pipe EndsEnd processing method Grid 300mm 40mm Grid area 150 mm Clamp support Check after pipingSpecifications of heating pipe Specifications of tube traceTroubleshooting of instrument TroubleshootingError codes and remedies Power supply Ambient temperaturePower consumption Mass weightStandard requirements For sample gas Month/NO2, 100ppmNumber of output points and kinds of outputs Moving average output Block diagramOrdering information Automatic calibrationCalibration tolerance Automatic calibration output hold Calibration cycle Once/day variable, up to 7 daysCode Symbols Diaglam Functions of individual components For indoor installation type For outdoor installation typeOnly specified outputs are wired Connection DiagramHead Office Instrumentation Div International Sales Dept