Energy-Saving Tips

Your Simplicity appliance is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency.

1)Select a thermostat setting that suits your comfort needs and leave at that chosen setting.

2)The air filter is very efficient in removing airborne particles. Keep the air filter clean at all times.

3)Use drapes, curtains or shades to keep direct sunlight from penetrating and heating room, but do not allow drapes or curtains to obstruct the air flow around the unit.

Window Installation

Electric Shock Hazard

To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.

CAUTION

To avoid installation/operation difficulties,

read these instructions thoroughly.

Installation Accessories Fig. 1

Description

Quantity

Flexible exhaust hose with adapters

3/set

stretches from 19 1/2" (50 cm) up to

 

74 3/4" (190 cm)

 

Window exhaust adapter (flat mouth)

1pc

Adjustable window/patio door slider kit

3/set

from 26 5/8" (67.5 cm) up to

 

80" (203 cm)

 

Drain hose connector

1 pc

continuous drain option (hose not included)

 

External Water Tank Accessories Fig. 1a

 

Support Tray & Castor

1 pc

External Tank & Cover

1 pc

Quick Connect (External Tank)

1 pc

SPECIAL NOTE: Exterior drain hose extension (direct drain) is not included with this unit and can be purchased through any local Hardware Store.

WARNING

When the patio door kit is installed, it will not be

possible to lock the patio door.

THIS COULD POSE A SECURITY RISK!

Installation of a “FOOTBOLT” or “DROP BAR” behind the door is suggested. (Available through most local hardware stores)

4)Start your air conditioner before the outdoor air becomes hot and uncomfortable. This avoids an initial period of discomfort while the unit is cooling off the room. Use of the automatic start/stop programmable TIMER feature can be a major asset in this regard if utilized to the fullest extent.

5)When outdoor temperatures are cool enough, turn the air conditioner off and use the FAN MODE on HIGH, MED or LOW. This circulates indoor air, providing some cooling comfort and utilizes less electricity.

The exhaust/window kit must be installed at all times when the unit is operating under the AIR CONDITIONING mode.

There should be at least 11.8" (30 cm) clearance between the unit and any other objects or building structure. The unit should be installed on a level surface. The window kit does not have to be installed during operation of the remaining three modes. (Heating/Dehumidifying/Fan).

Fig. 1 Installation Accessories

 

 

Drain Hose Connector

Flexible Exhaust Hose

Window Exhaust

Adapter

19 1/2" - 74 3/4"

 

 

Adapter

Adapter

Adjustable Window/Patio Door Slider Kit

 

 

26 5/8" - 80"

Fig. 1 a External Water Tank Accessories

Support Tray

Tank & Quick Connect

4

Image 10
Contents Appareil de confort au foyer portatif 4 saisons Portable 4 Season Home ComfortAparato de confort doméstico para 4 estaciones Manuel ’UTILISATION Manual DEL Propietario Table Of Contents Unit Parts IdentificationGarantia Limitada DEL Producto Servicio de GarantíaRemoción y limpieza del filtro de aire Cuidado y MantenimientoVuelva a colocar el filtro de aire This symbol denotes a caution or warning IntroductionPower Consumption Electrical SpecificationsUnit Specifications Model SPAC8499 Suggested Individual Branch CircuitVentana LCD Como el tanque de algua Externo funcionaTanque principal solamente Instrucciones para la operación Con el control remoto ModoExternal Water Tank Accessories a Window Installation Electric Shock HazardInstallation Accessories Fig Energy-Saving TipsExternal Water Tank Feature External Water Tank InstructionsBotones inferiores de control Propiedades del control remotoBotones superiores de control Se deben cambiar las pilas cuandoGraduación del Reloj DE Encendido Y Apagado Automático Figura 32aExternal Water Tank Instructions contd Operating Instructions Window / Patio Door Kit InstallationInternal Water Tank Safety Feature Before Starting This UnitGraduación del Reloj DE Apagado Automático 1200Graduación del Reloj DE Encendido Automático continúa Temperature Conversion Chart Key Pad Functions Fig1201 Setting Time of DAY Clock InstructionsAir Conditioner Operating Instructions 1200Encienda la unidad conmutador I/O Instrucciones para el reloj automáticoGraduación del Reloj DE Encendido Automático De visualización. FiguraInstrucciones para la operación del ventilador Baja-Mediana-AltaSet position excluding the top and/or bottom Air Conditioner Operating Instructions cont’dExcluding the top or bottom louver Louvers. FigDRY Dehumidifier Operating Instructions Luz roja Modo de Calefacción Instrucciones para la operación de la calefacción25¡c Velocidad del VentiladorAtención DRY Dehumidifier Operating Instructions cont’d FloodingRed Light Heat Mode Heater Operating InstructionsInstrucciones de operación para Secar Deshumidificador Luz verde Modo Seco¿Está lleno el tanque de agua? Oscilación Del aireFan Operating Instructions Fan ModeLow-Med-High Setting the AUTO-ON Timer Auto-Timer InstructionsTurn the unit on I/O switch 17C 63 F y 30C 88F. Figura Instrucciones para graduar la Hora DEL DÍA RelojInstrucciones de operación del acondicionador de aire Luz verdeTabla de conversión de temperaturas Funciones del teclado FiguraConmutador de corriente encendido/apagado All of the settings are now registered. Turn Setting the AUTO-ON Timer cont’dUnit OFF Using the I/O Switch Setting the AUTO-OFF Timer Antes de encender esta unidad Opción de seguridad del tangue de agua internoInstrucciones de operación Modo DE Aire AcondicionadoInstale la tapa sobre el tanque de agua Levante y tire hacia adelante. véase la figura 38Setting the AUTO-ON & AUTO-OFF Timer Unit must remain OFF while programming the AUTO-OFF programUpper Control Buttons Remote Control FeaturesBattery replacement Lower Control Buttons Under Lower Sliding CoverEl tanque de agua externo Accesorios para la instalación Figura Sugerencias para ahorrar energíaInstalación en la ventana AcondicionadoSetting/Adjusting Time of Day Clock Remote Control Operating InstructionsTemperature Setting Press the remote Mode FAN SpeedsSpecial Note Swing Setting Press the remote SwingAir Conditioner & Dehumidifier Modes Only Especificaciones Eléctricas TablaIntroducción Care and Maintenance Removal and Cleaning of the Air FilterWith-In United States Warranty ServiceHome Índice Identificación de las piezas de la unidadService sous-garantie Climatiseur CanadaTable des matières Identification des pièces de l’appareilSoins et entretien Réinstallez le filtreComment enlever et nettoyer le filtre à air Remarque Spéciale Instructions d’utilisation De la télécommande suiteCeci est normal RemarqueCe symbole représente une précaution ou un avertissement Types de prise et fusible Spécifications électriquesDérivation individuelle suggérée Spécification de l’appareil Modèle SPAC8499Instructions d’utilisation De la télécommande ModeLes piles doivent être remplacées lorsque Caractéristiques de la TélécommandeCommandes du premier niveau Comment changer les pilesConseil pour la conservation ’énergie Installation dans la fenêtreAccessoires d’installation Fig Être propreLe réservoir d’eau externe Réglage du minuteur AUTO-ON et Secondes. Appuyez sur les touchesRéglage du minuteur d’arrêt automatique Instructions d’installation du réservoir d’eau externe suite Installez le couvercle sur le réservoir d’eauInstruction d’utilisation Installation du jeu de fenêtre / porte patioMécanisme de sécurité du réservoir d’eau interne Avant de mettre l’appareil en marche’APPAREIL OFF EN Utilisant L’INTERRUPTEUR I/O Le réglage est maintenant complété. ArrêtezProgramme AUTO-ON. a Minuteur Automatique Sélection Du modeInstructions pour le minuteur automatique Mettez l’appareil en marche touche I/OLampe témoin de réservoir plein La lampe rouge Tableau de conversion de températureMise en marche/arrêt Interrupteur de mise en marche / arrêt Option de ventilationRefroidissement- chaleur- déshumidification-ventilation Réglage de l’HEURE horlogeInstructions d’utilisation du climatiseur Climatisation’exception du volet supérieur et inférieur. Fig Instructions d’utilisation du ventilateurLampe éteinte Température Instructions d’utilisation du radiateurLampe rouge Balayage d’airInstructions d’utilisation du climatiseur suite Marche Pendant CE DélaiInstructions d’utilisation du déshumidificateur Mode duRefroidissement-chaleur-déshumidification- ventilation Instructions d’utilisation du déshumidificateur suite