ENGLISH
SECTION 2 - INSTALLATION
IV. THERMOCOUPLE INSTALLATION
1.Install the thermocouple sensing bulb into the hole in the rear of the oven, as shown in Figure
2.Thread the thermocouple lead(s) through the grommet and into the machinery compartment, as shown in Figure
3.Remove the
4.Thread the thermocouple lead(s) through the side of the machinery compartment as shown in Figure
5.Connect the thermocouple leads to the temperature con- troller as shown in Figure
V. CONVEYOR INSTALLATION
NOTE
The conveyor assembly MUST be inserted from the drive end of the oven.
1.Lift the conveyor and position it in the oven as shown in Figure
2.Continue moving the conveyor into the oven until the lip on the bottom edge of the frame butts firmly against the end plug.
Figure 2-6 - Thermocouple Installation Location
Thermocouple
Grommet-
protected hole
Figure 2-7 - Placing the Thermocouple Leads
Figure 2-8 - Thermocouple Lead Connections
8=White=Positive
7=Red=Negative R=No Connection Ground=Shielded cable
| Figure |
|
1 | 2 | 3 |
Unfold
conveyor
Slide into drive
end of oven
Lip on bottom
edge of frame fits
against end plug
8