Wait for the Status LED and Master Mgt Module LED to light solid green. At this point the EMM will learn the default module and port settings for all modules installed in the concentrator.
Figure 2-1. Installing the Ethernet Management Module
2.Fasten the spring-loaded screws on the front panel of the EMM faceplate to the concentrator with your fingers (do not overtighten).
3.If a terminal (out-of-band) connection is desired, verify that the terminal meets the factory defaults of the EMM or you will not be able to communicate with the module. The default EMM settings are:
–9600 baud
–8 data bits
–No parity
–2 stop bits
4.Attach one end of an RS-232 cable to the RS-232 serial port connector on the front of the EMM. Loop the cable through the concentrator cable tray (if installed) and attach the other end to the RS-232 serial port connector on a terminal or personal computer as shown in Figure 2-2.
2 - 4 ONline Ethernet Management Module Installation and Operation Guide