Table 4-2. EMM Terminal Interface Suggestions (Continued)
Problem | Troubleshooting Suggestions |
|
|
The Master MGT Module LED | Check for multiple EMMs and verify |
blinks sporadically. | that only one has been set to a |
| mastership level of 10. |
|
|
The >> prompt appears on the | The EMM is running in maintenance |
screen. | mode. Type BOOT to return to |
| management mode and the ONline> |
| prompt. |
|
|
EMM Trap Messages
A trap message is sent to the console when a change is made or an error occurs in a concentrator that has an installed EMM. The trap is also sent to the designated trap receiver (e.g., management workstation) if you have entered this information in the EMM community table. For example, if a module is removed from a concentrator, a message that describes the change is sent to the console, as shown below:
Message received from this device on 15:28 Mon 09 Aug 93:
Enterprise: | Chipcom |
|
Enterprise | Specific Trap: | Slot Down |
Message Information: |
| |
Slot Number: | 6 | |
Module | Type Number: | 6 |
Module | Description: |
Troubleshooting 4 - 5