Table 3-2. EMM Terminal Parameter Options and Factory Defaults
Parameter | Options | Factory Default |
|
|
|
Baud | 300, 1200, 2400, 4800, 9600 | 9600 |
|
|
|
Data_bits | 7 or 8 | 8 |
|
|
|
Parity | odd, even, or none | none |
|
|
|
Stop_bits | 1 or 2 | 2 |
|
|
|
Once you have configured your terminal to match the factory defaults of the EMM, press [ENTER] and the following greeting is displayed:
Ethernet Management Module (v4.00) Copyright (c) 1993 Chipcom Corporation
Press [ENTER] again and the EMM prompts you for a password. Enter the password and then press [ENTER] (the default password is a null string). The following greeting and the default management prompt is displayed:
Welcome to system administrator service on ONline.
ONline>
You are now logged in as the administrator with full access to all commands. Once terminal settings are complete, you can configure the ONline System Concentrator, the newly installed EMM, and all other ONline modules residing in the concentrator.
When you are done using the EMM, save all changes, and then log out of the system using the LOGOUT command. Provided you have saved all changes before issuing this command, you are logged out of the system and the following message displays:
ONline> logout | [ENTER] |
Bye |
|
Startup and Management Functions 3 - 5