Logging Out From a Remote Session

When you no longer need to be connected to a remote device, enter the LOGOUT command. This command disconnects the remote connection and reconnects the session with the local EMM. Once this is done, the local management prompt returns to the local screen.

If TIMEOUT has been set for the remote EMM and the time runs out, you will be logged out of the remote EMM and returned to the local EMM. Unsaved changes are still in effect, but they will be lost if the EMM is reset. To save these changes, re-establish connection to the EMM and issue the SAVE command.

Monitoring With SHOW Commands

The EMM enables you to display device (EMM), module, port, and concentrator configuration settings using the SHOW commands.

Showing Device Information

Use the SHOW DEVICE command to view the current EMM information.

ONline> show device [ENTER]

3Com Advanced Ethernet Management Module (5101M-MGTA) v4.00.0 AgentOS SNMP

Name: ONline

 

 

Location:

Wiring Closet 3

 

 

For assistance contact: Network Administrator

 

Boot EPROM Version: v3.2

Serial

 

Number: 850836 Restarts: 7

 

 

Flash EPROM Version: v4.00-A

Service Date:

93/06/16

Network

IP Address

Subnet Mask

Default Gateway

1 *

151.104.002.205

FF.FF.00.00

151.104.002.001

2

151.104.006.214

FF.FF.00.00

151.104.006.001

3

151.104.006.214

FF.FF.00.00

151.104.006.001