IP Phone Administrator Guide Operational Features

Operational Features

Administrator Passwords

An administrator can change the administrator passwords on the phone using the configuration files only.

An administrator can also assign a password for using the Options key on the IP phone. You turn this feature on and off by entering the "options password enabled" parameter followed by a valid value in the configuration files. Valid values are 0 (false; Options key not password protected), or 1 (true; Options key password protected). If this parameter is set to 1, a user has to enter a password at the IP phone UI. If the password is entered correctly, the user is allowed to gain access to the Options Menu and no more password prompts display for other password protected screens. If the user fails to enter the correct password in three attempts, access to the Options Mneu is denied and the IP phoen returns to the idle screen.

Procedure

Use the following procedure to change the administrator password.

Configuration Files

For specific parameters you can set in the configuration files, seeAppendix A, the section, “Password Settings” on page A-8.

5-8

41-001129-00 Rev 09, Release 1.4.1

Page 120
Image 120
Aastra Telecom 480I CT manual Administrator Passwords, Procedure