Image 331

Configuration Parameters

Operational, Basic, and Advanced Parameters

Parameter

IP Phone UI

Options->SIP Settings

sip registrar port

Aastra Web UI

Advanced Settings->Global SIP->

 

 

Basic SIP Settings

Registrar Port

Configuration Files

aastra.cfg, <mac>.cfg

(in Web UI)

 

 

 

 

 

 

Description

The registrar's port number.

 

 

 

 

Format

Integer

 

 

 

 

 

 

Default Value

0

 

 

 

 

 

 

Range

Not Applicable

 

 

 

 

 

 

Example

sip registrar port: 5060

 

 

 

 

 

 

 

 

 

 

Parameter

Aastra Web UI

Advanced Settings->Global SIP->

 

sip backup registrar ip

 

Basic SIP Network Settings

Backup Registrar Server

Configuration Files

aastra.cfg, <mac>.cfg

 

 

 

(in Web UI)

 

 

 

 

 

Description

The address of the backup registrar (typically, the backup SIP proxy) for

 

 

which the IP phone uses to send REGISTER requests if the primary

 

registrar is unavailable.

 

 

 

A global value of 0.0.0.0 disables backup registration. However, the

 

phone is still active and you can dial using username@ip address of the

 

phone.

 

 

 

If the backup registrar IP address is set to 0.0.0.0 for a per-line basis (i.e,

 

line 1, line 2, etc.), then the backup register request is not sent, the "No

 

Service" message does not display, and the message waiting indicator

 

(MWI) does not come on.

 

 

Format

IP address or fully qualified Domain Name

 

 

 

 

 

Default Value

0.0.0.0

 

 

 

 

 

 

Range

Not Applicable

 

 

 

 

Example

sip backup registrar ip: 192.168.0.102

 

 

 

 

 