ADC Telecommunications, Inc.
184 CHAPTER 9: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)
■Interface-related events: Interface-related events refer to faults that
affect the link state of the interface.
Notice
■link up Link to IP network is operational. Notice
■link down Link to IP network is not operational. Error
■chassis-fault Auxiliary device-related event that refers to
faults associated to the fan tray, power
source and clock sources.
NOTE: Reference “Timing and Alarm
Module Fault Reporting” on page 155, for
a list of the chassis-related notific ation
types.
Critical
■chassis-fault-cleared Indicates the chassis event that caused a
fault is fixed.
Notice
Provisioning events: Provisioning events refer to fault s that
pertain to the FastFlow BPM running on
the Cuda 12000.
■duplicate-addr A duplicate IP address has been detected. Notice
■isp-addr-high The free IP address count exceeded the
upper threshold for the specified ISP.
Notice
■isp-addr-low The free address count fell below the
lower threshold for the specified ISP.
Notice
■ldap-failed A directory server access failure occurred. Notice
■ldap-restored Directory server access is operational after
a failure.
Notice
■prov-service A FastFlow BPM service started, stopped,
or failed.
Notice
■subnet-addr-high The free IP address count exceeded the
high available address threshold for a
subnet.
Notice
■subnet-addr-low The free IP address count fell below the
low available address threshold for a
subnet.
Notice
DOCSIS events: DOCSIS events refer to initialization fault s
on DOCSIS and EuroDOCSIS modules.
■docs-dyn-rsp-fail A dynamic service response failure
occurred during the dynamic services
process.
Warning
System Event Description Event Class