Cuda 12000 IP Access Switch CLI-based Administration Guide
Displaying Current Chassis Configuration 83
snmp-server group adc v3 noauth read public write private
notify public contex
t adc storage nonvolatile
snmp-server group mgr v3 noauth read nosnmpconfig context
monitor storage nonv
olatile
snmp-server group guitraps v1 notify guitraps storage readonly
snmp-server group guitraps v2c notify guitraps storage
readonly
snmp-server group superman v3 priv read allaccess write
allaccess context admi
n storage nonvolatile
snmp-server group admingroup v1 read allaccess write allaccess
storage nonvola
tile
snmp-server group admingroup v2c read allaccess write
allaccess storage nonvol
atile
snmp-server group monitorgroup v1 read nosnmpconfig storage
nonvolatile
snmp-server group monitorgroup v2c read nosnmpconfig storage
nonvolatile
snmp-server group trapcommunity v1 notify allaccess storage
nonvolatile
snmp-server group trapcommunity v2c notify allaccess storage
nonvolatile
snmp-server view public 1.3.6.1 included storage nonvolatile
snmp-server view private 1.3.6.1 included storage nonvolatile
snmp-server view guitraps 1.3.6.1 included storage readonly
snmp-server view allaccess 1.3.6.1 included storage
nonvolatile
snmp-server view nosnmpconfig 1.3.6.1 included storage
nonvolatile
snmp-server view nosnmpconfig 1.3.6.1.6.3 excluded storage
nonvolatile
snmp-server community admincon admingroup address
192.168.212.0 mask 255.255.2
55.0 storage nonvolatile
snmp-server community guitraps guitraps storage readonly
snmp-server community justme admingroup address 100.100.10.5
address 100.100.1
0.8 address 192.168.212.109 storage nonvolatile
snmp-server community monitor monitorgroup storage nonvolatile
snmp-server community private adc context adc storage
nonvolatile
snmp-server community public adc context adc storage
nonvolatile