Cuda 12000 IP Access Switch CLI-based Administration Guide
Configuring the Downstream Channel 387
Example Procedure of Downstream Configuration

The following procedure steps you through the process of configuring a

DOCSIS downstream channel. An example of a DOCSIS configuration

follows:

Task Command
1. View a list of CMTS
interfaces that you have
installed on your chassis.
You can do so by using a
combination BAS/UNIX
command.
show topology | include docs
2. Enter configuration mode
for the CMTS interface that
you want to configure.
interface cable <c/s/i>
3. Display the current
downstream configuration
for this CMTS card.
show interface cable <c/s/i> downstream
4. Set the downstream
channel status.
downstream no shutdown
(Sets the downstream channel status to up.)
downstream shutdown
(Sets the downstream channel status to
down.)
5. Set the downstream center
frequency. Acceptable
DOCSIS range: 93.0 MHz to
855 MHz.
downstream frequency <freq number>
6. Set the downstream
channel interleave depth
downstream interleave-depth
{8 | 16 | 32 | 64 | 128}