Network Performance Analyzer Reference | 5 |
Memory Requirements
Memory Requirements
The FrameScope Pro requires a CompactFlash™ card to store test results and network station lists. The amount of memory that each Autotest result takes up depends on the number of test and the number of iterations that you set before starting the test. The results require about 600 bytes per test plus 150 bytes per iteration for each test. There is a limit of 100 tests and a limit of 100 iterations. Therefore, the maximum results size is about 1.5 MB.
The Autotest suite storage requirement is only 350 bytes per test, so the maximum size is about 35 KB.
The station list storage requirement is 250 bytes per station with a maximum of about 1500 stations, so the maximum size is 375 KB.
The FrameScope Pro does not use any of the 4MB of internal
Flash memory for network test result storage.
The following table lists approximate record storage capacities when configured for a 32 MB removable CompactFlash™ card and for comparison, a 192 MB card. All sizes of CompactFlash™ will work as FrameScope Pro Network Autotest results storage.
Saved Test Results Capacities, assuming a 1 MB used for test suites and station lists
Autotest # | Iterations | Size of |
| Capacity (# of | |
|
| record |
| Records) |
|
|
|
|
|
|
|
|
|
|
| 32 MB | 192 MB |
|
|
|
| CFlash | CFlash |
|
|
|
| Card | Card |
|
|
|
|
| |
10 Autotests | 1 | 60 KB | 516 | 3183 | |
|
|
|
|
| |
10 Autotests | 100 | 156 KB | 198 | 1224 | |
|
|
|
|
| |
100 | 1 | 600 KB | 51 | 318 | |
Autotests |
|
|
|
|
|
|
|
|
|
| |
100 | 100 | 1.56 MB | 19 | 122 | |
Autotests |
|
|
|
|
|
|
|
|
|
|
|
Agilent FrameScope Pro User’s Manual | 163 |