3Voice Testing with the FrameScope Pro
Running a Voice Test
When the Start button is pressed in the SIP Setting Window, The FrameScope Pro registers with the registrar/ SIP Server as per the options selected by the user in the SIP setting Window asks to do so, before placing a call or sending an Invite message.
Else, it calls directly to the IP address specified in the SIP Server window.
The SIP call is placed to the Target Phone number with either G711
CompactFlashTM using the Save Results button.
Once the test stops, the SIP signaling log can be seen when user clicks on Details button. Graphical plots of the VoIP test results with respect to time can also be viewed offline. For further information on this topic refer to the section below.
90 | Agilent FrameScope Pro User’s Manual |