Network Testing with the FrameScope Pro

2

WireMap Adapter Testing

WireMap Adapter Operation

When the wiremap adapter is connected to the FrameScope, the FrameScope sends a sequence of DC, TTL level signals through the wire pairs in order of a few 100 milliseconds. For each step of this sequence of signalling, the DC voltage is measured by the receiver of the FrameScope. The FrameScope software identifies wiremap information based on the readings.

LED Indicators

The wiremap adapter has four LEDs, each connected to a wire pair. The wiremap adapter has four LEDs, each connected to a wire pair. During the test, the LEDs flash. Once the test is completed, the LEDs turn off.

Procedure for WireMap Testing

1Connect the FrameScope and cable under test to the WireMap Adapter.

2From the Network Main Menu, press Tools, then press WireMap.

3Click Start Test.

Agilent FrameScope Pro User’s Manual

77

Page 77
Image 77
Agilent Technologies N2620A user manual WireMap Adapter Operation, Procedure for WireMap Testing, LED Indicators