2Network Testing with the FrameScope Pro

Performance Tests

Frame loss rate settings screen

Select the frame direction to measure.(for loopback only bi direction is present)

Max Data Rate is used for initial frame speed and performance calculation. Enter the maximum data rate of the network under test. If not known, the link speed will be used.

Select full range to measure frame loss rate specified by step size or specific rate

Specify the frame length or select full range to collect all frames.

Duration is the time taken (in seconds) to transmit frames

For better results, adjust the duration to load the device under test sufficiently.

Back to Back settings screen

Select the frame direction to measure.(for loopback only bidirectional is present)

Specify the frame length or select full range to collect all frames.

Duration is the time taken (in seconds) to transmit burst frames

For better results, adjust the duration to load the device under test sufficiently.

7If a password is preset in the slave FrameScope, press the

Slave Password button on the master FrameScope to enter the

64

Agilent FrameScope Pro User’s Manual

Page 64
Image 64
Agilent Technologies N2620A user manual Back to Back settings screen