Quick Reference - 1

 

 

 

 

 

 

 

 

 

 

Front Panel Menus - At a Glance

 

 

 

 

 

 

 

 

 

Address

 

 

 

ADDRESS 5

Sets the GPIB Address

 

 

 

 

 

 

 

INTF GPIB

Selects an interface (GPIB or RS232)

 

 

 

 

 

R

 

 

 

 

 

 

 

 

BAUDRATE 300

Selects baud rate (300, 600, 1200, 2400, 4800, 9600) *

 

 

 

 

 

R

 

 

 

 

 

 

 

 

PARITY NONE

Selects message parity (NONE, EVEN, ODD, MARK, SPACE) *

 

 

 

 

 

R

 

 

 

 

 

 

 

 

FLOW NONE

Selects flow control (XON-XOFF, RTS-CTS, DTR-DSR, NONE) *

 

 

 

 

 

R

 

 

 

Recall

 

 

 

 

*RCL 0

 

 

Recalls the instrument state

 

 

 

 

 

 

 

*RST

 

 

Resets the instrument to its power-on state

 

 

 

 

 

R

 

 

 

 

 

Shift

 

 

Save

 

*SAV 0

 

 

Saves the present instrument state

 

 

Shift

 

Error

 

ERROR 0

Displays the number of errors in the SCPI error queue

 

 

Shift

 

 

Channel

 

CHANNEL 1

Allows selection of channel to be controlled by the front panel

 

 

 

 

 

 

 

 

 

 

 

 

 

Shift

 

Sense

 

S:PNT

 

 

Defines the number of data points in the measurement

 

 

 

 

 

R

 

S:TIN

 

 

Sets the digitizer sample spacing

 

 

 

 

 

 

 

S:WIN

 

 

Sets the measurement window function (RECT, HANN)

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

S:OFF

 

 

Defines the data offset in the measurement

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

S:C:RNG

 

Selects the current measurement range

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

S:V:RNG

 

Selects the voltage measurement range

 

 

 

 

 

R

 

 

 

 

Func

 

 

 

 

FUNC

 

 

Sets the regulation mode (CURR, RES, VOLT)

 

 

 

 

 

R

 

FNC:MODE

Selects what controls regulating mode (FIX, LIST)

 

 

 

 

 

 

 

INP:SHOR

Enable/disables the input short (OFF/ON)

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

Protect

 

 

 

OC --

--

--

General protection status (overcurrent fault shown)

 

 

 

 

 

R

 

RRV ---

--

Voltage protection status (remote reverse voltage fault shown)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Meter

 

 

 

XXXX

XXXX

Displays the input voltage and current

 

 

 

 

 

R

 

XXXX V MAX

Displays the maximum voltage

 

 

 

 

 

 

 

XXXX V MIN

Displays the minimum voltage

 

 

 

 

 

R

 

 

 

 

 

 

 

 

XXXX V RMS

Displays the rms voltage

 

 

 

 

 

R

 

 

 

 

 

 

 

 

XXXX A MAX

Displays the maximum current

 

 

 

 

 

R

 

 

 

 

 

 

 

 

XXXX A MIN

Displays the minimum current

 

 

 

 

 

R

 

 

 

 

 

 

 

 

XXXX A RMS

Displays the rms current

 

 

 

 

 

R

 

 

 

 

 

 

 

 

XXXX WATTS

Displays the wattage

 

 

 

 

 

R

 

 

 

 

 

 

 

 

XXXX W MAX

Displays the maximum wattage

 

 

 

 

 

R

 

 

 

 

 

 

 

 

XXXX W MIN

Displays the minimum wattage

 

 

 

 

 

R

 

 

 

Current

 

 

 

CURR

 

 

Sets the input current

 

 

 

 

 

R

 

C:MODE

 

Sets the current mode (FIXED, LIST)

 

 

 

 

 

 

 

C:RANG

 

Sets the input current range

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

C:SLEW

 

Sets current slew rate

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

C:SLW:N

 

Sets current slew rate for negative transitions

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

C:SLW:P

 

Sets current slew rate for positive transitions

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

C:TLEV

 

Sets the transient input current

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

C:TRIG

 

Sets the triggered input current

 

 

 

 

 

R

 

 

 

 

Res

 

 

 

RES

 

 

Sets the input resistance

 

 

 

 

 

R

 

R:MODE

 

Sets the resistance mode (FIXED, LIST)

 

 

 

 

 

 

 

R:RANG

 

Sets the input resistance range

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

R:SLEW

 

Sets resistance slew rate

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

R:SLW:N

 

Sets resistance slew rate for negative transitions

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

R:SLW:P

 

Sets resistance slew rate for positive transitions

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

R:TLEV

 

Sets the transient input resistance

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

R:TRIG

 

Sets the triggered input resistance

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

*Only applicable for use with RS-232

 

15