A - Specifications

Table A-1. Specifications (continued)

N3302A

N3303A

N3304A

N3305A

N3306A

Constant Current Mode2

Low Range/High Range

Regulation

Low Range Accuracy

High Range Accuracy

Constant Voltage Mode2

Low Range/High Range

Regulation

Low Range Accuracy

High Range Accuracy

Constant Resistance Mode2

Range 1 (I >10% of current rating) Accuracy up to 25% of range Accuracy >25% to 50% of range Accuracy >50% to 100% of range

Range 2 (I >1% of current rating) Accuracy up to 25% of range Accuracy >25% to 50% of range Accuracy >50% to 100% of range

Range 3 (I >0.1% of current rating) Accuracy up to 25% of range Accuracy >25% to 50% of range Accuracy >50% to 100% of range

Range 4 (I >0.01% of current rating) Accuracy up to 25% of range Accuracy >25% to 50% of range Accuracy >50% to 80% of range Accuracy >80% to 100% of range

3A / 30A

10mA

0.1% + 5mA

0.1% + 10mA

6V / 60V

5mV

0.1% + 3 mV

0.1% + 8 mV

0.067-4 Ω

0.4% ± 24mΩ

0.4% ± 24mΩ

0.8% ± 24mΩ

3.6-40 Ω

1.5% ±80mΩ

2% ±80mΩ

3% ±80mΩ

36-400 Ω

8% ±240mΩ

16% ±240mΩ

32% ±240mΩ

360-2000Ω -25/+100% -25/+100% -40/+400% -40/+400%

1A / 10A

8mA

0.1% + 4mA

0.1% + 7.5mA

24V / 240V

10mV

0.1% + 10mV

0.1% + 40mV

0.2-48 Ω

1% ± 100mΩ

2% ± 100mΩ

3% ± 100mΩ

44-480 Ω

5% ± 500mΩ

10% ± 500mΩ

20% ± 500mΩ

440-4800Ω -30/+50% -40/+133% -50/+600%

4400-12000Ω -66/+800% -66/+800% -66/+800% -66/+800%

6A / 60A

10mA

0.1% + 7.5mA

0.1% + 15mA

6V / 60V

10mV

0.1% + 3 mV

0.1% + 8mV

0.033-2 Ω

0.4% ±12mΩ

0.4% ±12mΩ

0.4% ±12mΩ

1.8-20 Ω

1.5% ±40mΩ

2% ±40mΩ

3% ±40mΩ

18-200 Ω

6% ±120mΩ

10% ±120mΩ

20% ±120mΩ

180-2000Ω -20/+66% -33/+200% -45/+600% -50/+2000%

6A / 60A

10mA

0.1% + 7.5mA

0.1% + 15mA

15V / 150V

10mV

0.1% + 10mV

0.1% + 20mV

0.033-5 Ω

0.4% ± 24mΩ

0.4% ± 24mΩ

0.8% ± 24mΩ

4.5-50 Ω

1.5% ±80mΩ

2% ±80mΩ

3% ±80mΩ

45-500Ω -10/+25% -20/+50% -30/+150%

450-2500Ω -35/+200% -45/+500% -50/+1200% -50/+2000%

12A / 120A

10mA

0.1% + 15mA

0.1% + 37.5mA

6V / 60V

20mV

0.1% + 3mV

0.1% + 8mV

0.017-1 Ω

0.4% ± 6mΩ

0.4% ± 6mΩ

0.4% ± 6mΩ

0.9-10 Ω

1.5% ±20mΩ

2% ±20mΩ

3% ±20mΩ

9-100 Ω

6% ±60mΩ

10% ±60mΩ

20% ±60mΩ

90-1000Ω -20/+66% -33/+200% -45/+600% -50/+2000%

Transient Generator

Frequency Range

Frequency Accuracy

Duty Cycle Range

Duty Cycle Accuracy3 Pulse Width

Current Measurement2

Low Range / High Range

Low Range Accuracy4

High Range Accuracy4

Voltage Measurement2

Low Range / High Range

Low Range Accuracy

High Range Accuracy

Power Measurement2

Accuracy

0.25Hz -10kHz

0.5%

3 to 97% (0.25Hz - 1kHz)

6 to 94% (1kHz - 10kHz)

1%

50μs ± 1% to 4 seconds ± 1%

3A / 30A

 

1A / 10A

 

6A / 60A

 

6A / 60A

 

12A / 120A

0.05% + 3mA

 

0.05%

+ 2.5mA

 

0.05%

+ 5mA

 

0.05%

+ 5mA

 

0.05%

+ 10mA

0.05% + 6mA

 

0.05%

+ 5mA

 

0.05%

+ 10mA

 

0.05%

+ 10mA

 

0.05%

+ 20mA

6V / 60V

 

24V / 240V

 

6V / 60V

 

15V / 150V

 

6V / 60V

 

 

 

 

0.05% + 3mV

 

0.05%

+ 10mV

 

0.05%

+ 3 mV

 

0.05%

+ 8mV

 

0.05%

+ 3mV

0.05% + 8mV

 

0.05%

+ 20mV

 

0.05%

+ 8 mV

 

0.05%

+ 16mV

 

0.05%

+ 8mV

0.1% + 0.5W

 

0.1% + 1.2W

 

0.1% + 0.5W

 

0.1% + 1.5W

 

0.1% + 1.2W

 

 

 

 

2Specification is +/-(% of reading + fixed offset). Measurement is 1000 samples. Specification may degrade when the unit is subject to an RF field of 3V/meter, the unit is subject to line spikes of 500V, or an 8kV electrostatic discharge.

3For example, if the duty cycle setting is 20%, the actual duty cycle would be in the range of 19% to 21%.

4DC current accuracy specifications apply 30 seconds after input current is applied.

72