Front Panel Operation - 5

Transient Control Keys

Transient control keys control the transient functions of the electronic load.

Tran

Press this key to access the function menu.

Display

Command Function

TRAN <value>

Sets the current of input

T:DCYC

Sets the current mode to FIX or LIST

T:FREQ

Sets the current slew rate for both positive and negative transitions

T:MODE

Sets the current slew rate for the negative transitions

T:TWID

Sets the current slew rate for the positive transitions

Trigger Control Keys

Trigger control keys control the trigger functions of the electronic load.

Trigger Control

Press this key to access the function menu.

Display

Command Function

INIT:IMMED

Sets the current of input

ABORT

Sets the current mode to FIX or LIST

List Control Keys

List control keys control the list functions of the electronic load.

List

Press this key to access the function menu.

Display

Command Function

LIST:STEP

Sets the method of incrementing steps (ONCE, AUTO)

LST:CNT

Specifies the number of times the list is cycled

DWEL:0 EOL

Specifies the time period of each step

CURR:0 EOL

Specifies the current setting for each step

C:RANG:0 EOL

Specifies the current range for each step

C:SLEW:0 EOL

Sets the current slew rate for each step

C:SLW:N:0 EOL

Sets the negative current slew rate for each step

C:SLW:P:0 EOL

Sets the positive current slew rate for each step

C:TLEV:0 EOL

Sets the transient input current for each step

FUNC:0 EOL

Sets the list regulation mode (CURR, RES, VOLT)

RES:0 EOL

Specifies the resistance setting for each step

R:RANG:0 EOL

Specifies the resistance range for each step

R:SLEW:0 EOL

Sets the resistance slew rate for each step

R:SLW:N:0 EOL

Sets the negative resistance slew rate for each step

R:SLW:P:0 EOL

Sets the positive resistance slew rate for each step

R:TLEV:0 EOL

Sets the transient input resistance for each step

TRAN:0 EOL

Enables/disables the transient level for each step

T:DCYC:0 EOL

Sets the transient duty cycle for each step

T:FREQ:0 EOL

Sets the transient frequency for each step

T:MODE:0 EOL

Sets the mode of the transient generator (CONT, PULSE)

T:TWID:0 EOL

Sets the transient pulse width for each step

VOLT:0 EOL

Specifies the voltage setting for each step

V:RANG:0 EOL

Specifies the voltage range for each step

V:SLEW:0 EOL

Sets the voltage slew rate for each step

V:SLW:N:0 EOL

Sets the negative voltage slew rate for each step

V:SLW:P:0 EOL

Sets the positive voltage slew rate for each step

V:TLEV:0 EOL

Sets the transient input voltage for each step

61