Asante Technologies 5308F user manual Rising Threshold, Falling Threshold, Rising Event Index

Models: 5308F

1 152
Download 152 pages 946 b
Page 118
Image 118

Advanced Management

fallingAlarm — if the first sample is less than or equal to the value set for the Falling Threshold (see “Falling Threshold” below), an alarm is generated.

risingOrFallingAlarm — sets both rising and falling alarms.

Rising Threshold

Enter the number of the threshold for the sampled statistic.

When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated.

Falling Threshold

Enter the number of the threshold for the sampled statistic.

When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated.

Rising Event Index

Enter the number of the Event entry that was created for this Alarm entry.

This number references the Event entry that is to be utilized when a rising threshold is crossed. If there is no corresponding entry in the eventTable, or if this value is zero, no associated event will be generated.

Falling Event Index

Enter the number of the Event entry that you created for this Alarm entry.

This number references the Event entry that is to be utilized when a rising threshold is crossed. If there is no corresponding entry in the eventTable, or if this value is zero, no associated event will be generated.

Owner String

Enter name of the person or entity who defined the entry.

3 Type y at the prompt to set the parameters.