Adding an RMON History Control Group Entry

Command Prompts

Figure 7-3

Add RMON History Control Group entry

2

Enter the information requested for each

 

prompt, following the guidelines below.

Data Source (Interface Number)

Enter the number of the port for which statistics are to be gathered.

Requested Buckets

Enter the number of discrete time intervals over which data is to be saved. This number can be between 1 and 10.

Sampling Interval

Enter the interval (in seconds) over which the data is to be sampled for each bucket. This interval can be set to any number of seconds between 1 and 3600 (1 hour).

Owner String

Enter the name of the person who configured this entry. This value is used for tracking purposes; it can be any text or integer.

3

Type y at the prompt to set the parameters,

 

or type n to cancel.

Page 7-5

Page 111
Image 111
Asante Technologies 5308F Adding an Rmon History Control Group Entry, Data Source Interface Number, Requested Buckets