Asante Technologies 5308F Troubleshooting, LED Error Type/Cause Solution Options or Steps

Models: 5308F

1 152
Download 152 pages 946 b
Page 127
Image 127

Appendix A

Troubleshooting

This section provides some diagnostic tips for troubleshooting problems with your network and the IntraSwitch 5308FL.

LED Indicators The following table describes some possible errors and solutions for troubleshooting problems via the IntraSwitch 5308FL’s LEDs.

Table A-1 Troubleshooting Tips

LED Error Type/Cause

Solution (Options or Steps)

Power LED does not come on when the power cord is connected to an outlet

AC power source is not opera- tional.

Power cord not connected/faulty.

Internal power supply has failed.

Check the AC power source.

Connect/replace the power cord.

If configured, ensure redundant DC power supply is connected and is operating (schedule time to return unit for repair).

Data LED for the port never comes on

Cable connection is broken or faulty.

Equipment to which the port is connected is not operating.

Make sure the LINK LED is on; if the LINK LED is off, replace cable.

Make sure the device to which the port is connected is operat- ing properly.

Page A-1