Before installing the IntraSwitch 5308FL, carefully review the following guidelines.
Power Requirements
The source electrical outlet should be installed near the IntraSwitch 5308FL, be easily accessible, and be properly grounded.
Make sure the power source adheres to the following guidelines:
❏Voltage range: 100 to 240 VAC
❏Frequency range: 60/50 Hz
❏Maximum current: 1.6 A
Environmental Requirements
The IntraSwitch 5308FL must be installed in a clean, dry, dust- free area with adequate air circulation to maintain the following environmental limits:
❏Temperature: 0° to 45° C
❏Relative Humidity: 5% to 85%
Avoid direct sunlight, heat sources, or areas with high levels of
Cooling and Airflow
The IntraSwitch 5308FL has two internal fans that cool the interior by drawing air through vents on the sides and forcing heated air out through holes in the rear.
▲Important! Do not restrict air flow by covering or obstructing air vents on the sides of the case.