3-14 User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
Chapter 3
2. In the Slot 1 Sensor and Backplane Sensor fields, enter the desired
temperature warnings.
* Note: The P882 does not display the current temperature of the
backplane. In the Current Temperature field, the switch
displays --.
* Note: If a redundant Supervisor module is installed, the Slot 2 Sens or
column displays.
* Note: You cannot change settings for the backplane temperature
sensors on the P882. If you attempt to change the settings, the
switch displays the following error message:
Set Limits for Backplane Sensor failed -
failure writing to sensor
3. In the CPU Sensor fields, enter the desired tempera ture warnings.
4. Click APPLY to save your changes, or DEFAULTS to reset the fields to
their default settings.
5. If you change the temperature ranges for the active supervisor, you must
synchronize the active and standby supervisors to copy the temperature
settings to the standby supervisor.
CLI Command To check the temperature stat us, use the show temperature CLI command.
To set the temperature thresholds, use the foll ow ing CLI commands:
(configure)# set temperature {supervisor-slot | backplane-
sensor | cpu-sensor | probe} shutdown <temperature>
(configure)# set temperature {supervisor-slot | backplane-
sensor | cpu-sensor | probe} warning {upper | lower | low-limit}
<temperature>