21-18 User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
Chapter 21
To disable utilization monitoring, enter Global Configuration mode and use
the following command:
clear utilization monitoring {cpu | forwarding-engine}
Enabling Event Logging of Utilization
To enable event logging of utilization, enter Global Configuration mode and
use the following command:
set utilization threshold-event {cpu | forwarding-engine}
The default setting for event logging of utilization is disabled . If you ena ble
event logging of utilization but do not specify a utilization threshold, the
switch logs an event if the CPU utilization or forwarding engine utilization
exceeds 95 percent.
To disable event logging of utilization, enter Global Configuration mode
and use the following command:
clear utilization threshold-event {cpu | forwarding-engine}
Table 21-7. Keywords, Arguments, and Options
Keyword, Argument, or
Option Definition
cpu Enables monitoring of CPU utilization.
forwarding-engine Enables monitoring of 80-series forwarding
engines.
Table 21-8. Keywords, Arguments, and Options
Keyword, Argument or
Option Definition
cpu Enables event logging for CPU utilization.
forwarding-engine Enables event logging for utilization of 80-
series forwarding engines.