8-54 User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
Chapter 8
Error Messages
* Note: If IEDR detects errors on a port in the h unt group, it tests each
port within that hunt group. When it finds the first bad port, it
removes it from the hunt group and disables the port.
The IEDR feature may display the f o llowing error messages:
The following message indicates the IEDR feature is enabled on t he
specified ports
internal-error-config enabled on port <x>/
<y>
The following message indicates that internal CRC errors are
occurring:
Description: CRC err: Rx’ed 5 bad pkts
since last poll - last from port3.2
The following message indicates that IEDR shut down a port
because its rate of internal errors exceeded the threshold:
Description: Shutdown Port 3.2 due to CRC
error exceeding threshold of 10
System Messages
The set port internal-error-shutdown all-ports enable command
produces system messages simila r to the following:
Upon success:
Internal-error-config enabled on port 3/1
Internal-error-config enabled on port 3/2
Internal-error-config enabled on port 4/1
Internal-error-config enabled on port 4/2
Internal-error-config enabled on port 4/3
Internal-error-config enabled on port 4/4
Slot 6 has 10/100 ethernet ports that are
unsupported and will not be set.
* Note: IEDR is supported only for 50-series and 80-series Gigabit
modules.