Chapter 10 Adjustment

1.Dismount the pulley cover and turn the pulley B q until the pulley scale indicates 180˚ and the needle bar is set at the lowest position. (The pulley B "" mark and the stop mark "" are aligned.)

2.Insert the positioning bar w into the hole of the pulley B q and fix the drive shaft.

Note) Turn the pulley B securely in the clockwise direction to eliminate a backlash.

3.Loosen Needle bar guide bracket set screw e and the bolt u of the top dead center stopper t when the needle tip is positioned 10.8 mm above the center of the rotary hook shaft. Adjust the position of the needle bar thread guide so that the set screw r on it is turned to the right by 25 ~ 30˚. Tighten Needle bar guide bracket set screw e securely.

Note) When tightening the needle bar clamp set screw e, the hole in the needle bar guide should face the front.

4.After adjustment is finished, remove the positioning bar w.

5.Set the needle bar at the highest position (where the pulley B indication mark " " and the cover indication mark " " are aligned). Lightly press the top dead center stopper t toward the cushion rubber y, and tighten Socket head bolt for top dead center stopper u while pressing down the needle bar clamp so that it faces the front. (Tightening torque: 0.78 N.m)

Note) • Make sure that the top dead center stopper does not hit the needle bar guide rail i at this time.

BES-962BCBES-1262BC

233

Page 235
Image 235
Brother BES-962BC instruction manual 233